ASMNG/3/CONFIRM_AS_FAIL
Possible Causes
- Cause 1: Failed to check the record of the authenticated AS.
- Cause 2: Failed to add the AS's MAC address to the whitelist.
Procedure
- Run the display as command to check whether the AS's MAC address in the command output is consistent with the actual one.
- If so, go to step 2.
- If not, run the confirm command to confirm the AS allowed to pass authentication. If the fault persists, go to step 2.
- A flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel. You can collect diagnostic information using the display diagnostic-information command.
ASMNG/3/CREATE_SLOT_FAIL
ASMNG/3/DEL_AS_FAIL
Procedure
- According to the error information displayed during the operation, delete other configurations of the AS, such as the fabric port binding configuration and template configuration.
- Run the undo as name command to delete the AS.
- If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
ASMNG/3/DEL_SLOT_FAIL
Parameters
Parameter Name | Parameter Meaning |
---|---|
AS Name | Indicates the AS name. |
Slot ID | Indicates a slot ID. |
Procedure
- According to the error information displayed during the operation, delete other configurations of the AS, such as the fabric port binding configuration and template configuration.
- Run the undo slot command to delete the slot on the AS.
- If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
ASMNG/3/READ_ASINDEX_FAIL
Procedure
- Run the undo uni-mng command to delete the SVF configuration.
- Reconfigure SVF.
- If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
ASMNG/3/READ_MANMAC_FAIL
Procedure
- Enable the AS to read the management MAC address from the flash memory again after this AS is restarted. For details about restarting an AS, see "Restarting an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
ASMNG/3/READ_PSK_FAIL
Procedure
- Enable the AS to read the pre-shared key from the flash memory again after this AS is restarted. For details about restarting an AS, see "Restarting an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
ASMNG/3/REPLACE_SLOT_FAIL
Message
ASMNG/3/REPLACE_SLOT_FAIL: Failed to replace slot on AS. (AS Name=[STRING], Slot ID=[INTEGER])
Parameters
Parameter Name | Parameter Meaning |
---|---|
AS Name | Indicates the AS name. |
Slot ID | Indicates a slot ID. |
Possible Causes
Failed to run the slot slot-id1 replace-model model-name or slot slot-id2 [ to slot-id3 ] [ replace-model model-name ] command replace the slot on the AS.
Procedure
- Run the display as command to check whether the AS is online.
- If so, go to step 2.
- If not, go to step 4.
- Run the display uni-mng interface fabric-port state command to check the Local-port connected to this AS.
- In the stack port view, run the shutdown interface command to shut down this port.
- Run the display this command in the AS view to check whether this AS has other configurations, such as the fabric port binding configuration and template configuration. If so, delete these configurations.
- Run the slot command in the AS view to replace the slot on the AS again.
- If the fault persists, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
ASMNG/3/RESET_AS_FAIL
Procedure
- Restart the AS again. For details about restarting an AS, see "Restarting an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- Run the display as command to check whether this AS is online.
- If so, the AS is restarted successfully.
- If not, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
ASMNG/3/SAVE_ASINDEX_FAIL
Procedure
- Run the undo uni-mng command to delete the SVF configuration.
- Reconfigure SVF.
- If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
ASMNG/3/SAVE_MANMAC_FAIL
Procedure
- Enable the AS to save the management MAC address to the flash memory again after this AS is restarted. For details about restarting an AS, see "Restarting an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
ASMNG/3/SAVE_PSK_FAIL
Procedure
- Enable the AS to save the pre-shared key to the flash memory again after this AS is restarted. For details about restarting an AS, see "Restarting an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
ASMNG/3/SEND_MANMAC_FAIL
Message
ASMNG/3/SEND_MANMAC_FAIL: Failed to send the management MAC to other board. (Slot ID=[INTEGER])
Procedure
- Enable the AS to send the management MAC address to another slot again after this AS is restarted. For details about restarting an AS, see "Restarting an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
ASMNG/3/SEND_PSK_FAIL
Message
ASMNG/3/SEND_PSK_FAIL: Failed to send the pre-shared key to other board. (Slot ID=[INTEGER])
Procedure
- Enable the AS to send the pre-shared key to another slot again after this AS is restarted. For details about restarting an AS, see "Restarting an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S7700 V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
- If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
- ASMNG/3/CONFIRM_AS_FAIL
- ASMNG/3/CREATE_SLOT_FAIL
- ASMNG/3/DEL_AS_FAIL
- ASMNG/3/DEL_SLOT_FAIL
- ASMNG/3/READ_ASINDEX_FAIL
- ASMNG/3/READ_MANMAC_FAIL
- ASMNG/3/READ_PSK_FAIL
- ASMNG/3/REPLACE_SLOT_FAIL
- ASMNG/3/RESET_AS_FAIL
- ASMNG/3/SAVE_ASINDEX_FAIL
- ASMNG/3/SAVE_MANMAC_FAIL
- ASMNG/3/SAVE_PSK_FAIL
- ASMNG/3/SEND_MANMAC_FAIL
- ASMNG/3/SEND_PSK_FAIL