S12700 and S12700E V200R019C10 Configuration Guide - Network Management and Monitoring
This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, RMON2, LLDP, Performance Management, iPCA, NQA, Service Diagnosis, Mirroring, Packet Capture, Traffic Distribution, NetStream, sFlow, TWAMP Light, NETCONF, eMDI, and Intelligent Video O&M.
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document.
Note: Even the most advanced machine translation cannot match the quality of professional translators.
Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the NQA Client to Send Traps When a Probe Fails
Configuring the NQA Client to Send Traps When a Probe Fails
Context
Path jitter test test does not support the traps for probe failures.
Procedure
Run system-view
The system view is displayed.
Run nqatest-instanceadmin-nametest-name
The NQA view is displayed.
Run send-trapprobefailure
The NQA client is configured to send traps when a probe fails.
By default, the NQA client sends no trap when a probe fails.
Run probe-failtimestimes
The threshold on the traps sent after the probe fails is configured. The threshold specifies the maximum number of continuous probe failures for the NQA test instance.
By default, a trap is sent for each probe failure.