HUAWEI-PWE3-MIB
Functions Overview
Pseudo-Wire Emulation Edge to Edge (PWE3) is an end-to-end technology used to bear Layer 2 services, and belongs to the Layer 2 virtual private network (L2VPN) in the point-to-point mode. PWE3 adopts the Label Distribution Protocol (LDP) as the signaling mode, emulates Layer 2 services such as Layer 2 data packets on the Customer Edge (CE) through tunnels such as Multi-protocol Label Switch Protocol Label Switched Paths (MPLS LSPs), or Generic Routing Encapsulation (GRE) tunnels, and transparently transmits the Layer 2 data of the CE in the PSN network. This emulation is proximate but not absolute. For example, this proximate emulation may cause distortion for the Time Division Multiplexing (TDM) data.
The related draft of PWE3 provides the public MIB. The draft is constantly updated and is not completely consistent with the PWE3 implementation of the device, so the private MIB is defined for the PWE3 module. The task of this module is to implement the functions defined by the private MIB on the managed devices. The PWE3 MIB contains the public MIB.
The OID of the root object is as follows:
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).huawei(2011).huaweiMgmt(5).hwDatacomm(25).hwL2Vpn(119).hwL2VpnPwe3(4)
Relationship Between Tables
Description of Single Objects
hwPWVcStateChangeReason
OID |
Object Name |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.1.8 |
hwPWVcStateChangeReason |
INTEGER{invalidReason(1),vcCreated(2),vcDeleted(3),ldpSessionDown(4),ldpSessionUp(5),receivedDifLabelOrMtu(6),receivedIntfParaMatching(7),receivedIntfParaUnMatched(8),receivedUnPassCbitCheck(9),receivedUnPassPwLoopCheck(10),receivedNewMapping(11),receivedNewMappingButRemoteVcDown(12),receivedWithdrawn(13),receivedLdpRelease(14),receivedLdpRequest(15),ldpGrEndProcessing(16),receivedRsvpMessage(17),interfaceUp(18),interfaceDown(19),interfaceEncapChanged(20),refresh(21),downloadAgain(22),tunnelUp(23),tunnelDown(24),receivedNewRlb(25),deletedRlb(26),vcCreatedOrTurnedToAnother(27),outInterInInvalidState(28),outInterInValidNow(29),ldpNotifiForward(30),ldpNotifiNotForward(31),pwRestart(32),downloadFtnAndIlmForEthTrunk(33),acOamFaultDetectDisable(34),remoteAcFault(35),remoteAcFaultResume(36),localAcFault(37),localAcFaultResume(38),remotePsnFault(39),remotePsnFaultResume(40),localPsnFault(41),localPsnFaultResume(42),bfdForPwStateChangeToDown(43),bfdForPwStateChangeToUp(44),bfdForPwStateChangeToAdminDown(45),bfdForPwDisable(46),manualSetEnable(47),manualSetDisable(48),delayTimeOut(49),resumeTimeOut(50),vrrpMaster(51),vrrpBackup(52),vrrpInit(53),vrrpDelete(54),vrrpTrack(55),undoVrrpTrack(56),lspPingTimeOut(57),vcDownWhenReceivedNewRLB(58),mtuMatched(59),mtuUnmatched(60),vsiShut(61),vsiResume(62),setAdminVSI(63),undosetAdminVSI(64),bvsiBindAc(65),bvsiUnbindAc(66),ivsiBindBVSI(67),ivsiUnbindBVSI(68),deletedVSI(69),reconstructFwdTable(70),mclagMaster(71),mclagBackup(72),adminPwUp(73),adminPwDown(74),vccvOk(75),vccvFailed(76),localIfnetOk(77),inVcLabelOk(78),localIfnetRelease(79),inVcLabelRelease(80),switchOverEnable(81),switchOverDisable(82),setBVSI(83),undoSetBVSI(84),shutdownBVSI(85),undoShutdownBVSI(86),notificationReceived(87),pwApsSwitch(88),routeUnreachable(89),routeReachable(90),aging(91),verification(92),tdmBitRateMatched(93),tdmBitRateUnmatched(94)} |
Accessible-for-notify |
The value of this object identifies the reason for the PWVC status change. |
This object is implemented as defined in the corresponding MIB files. |
hwSvcStateChangeReason
OID |
Object Name |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.3.7 |
hwSvcStateChangeReason |
INTEGER{invalidReason(1),vcCreated(2),vcDeleted(3),ldpSessionDown(4),ldpSessionUp(5),receivedDifLabelOrMtu(6),receivedIntfParaMatching(7),receivedIntfParaUnMatched(8),receivedUnPassCbitCheck(9),receivedUnPassPwLoopCheck(10),receivedNewMapping(11),receivedNewMappingButRemoteVcDown(12),receivedWithdrawn(13),receivedLdpRelease(14),receivedLdpRequest(15),ldpGrEndProcessing(16),receivedRsvpMessage(17),interfaceUp(18),interfaceDown(19),interfaceEncapChanged(20),refresh(21),downloadAgain(22),tunnelUp(23),tunnelDown(24),receivedNewRlb(25),deletedRlb(26),vcCreatedOrTurnedToAnother(27),outInterInInvalidState(28),outInterInValidNow(29),ldpNotifiForward(30),ldpNotifiNotForward(31),pwRestart(32),downloadFtnAndIlmForEthTrunk(33),acOamFaultDetectDisable(34),remoteAcFault(35),remoteAcFaultResume(36),localAcFault(37),localAcFaultResume(38),remotePsnFault(39),remotePsnFaultResume(40),localPsnFault(41),localPsnFaultResume(42),bfdForPwStateChangeToDown(43),bfdForPwStateChangeToUp(44),bfdForPwStateChangeToAdminDown(45),bfdForPwDisable(46),manualSetEnable(47),manualSetDisable(48),delayTimeOut(49),resumeTimeOut(50),vrrpMaster(51),vrrpBackup(52),vrrpInit(53),vrrpDelete(54),vrrpTrack(55),undoVrrpTrack(56),lspPingTimeOut(57),vcDownWhenReceivedNewRLB(58),mtuMatched(59),mtuUnmatched(60),vsiShut(61),vsiResume(62),setAdminVSI(63),undosetAdminVSI(64),bvsiBindAc(65),bvsiUnbindAc(66),ivsiBindBVSI(67),ivsiUnbindBVSI(68),deletedVSI(69),reconstructFwdTable(70),mclagMaster(71),mclagBackup(72),adminPwUp(73),adminPwDown(74),vccvOk(75),vccvFailed(76),localIfnetOk(77),inVcLabelOk(78),localIfnetRelease(79),inVcLabelRelease(80),switchOverEnable(81),switchOverDisable(82),setBVSI(83),undoSetBVSI(84),shutdownBVSI(85),undoShutdownBVSI(86),notificationReceived(87),pwApsSwitch(88),routeUnreachable(89),routeReachable(90),aging(91),verification(92),tdmBitRateMatched(93),tdmBitRateUnmatched(94)} |
Accessible-for-notify |
The value of this object identifies the reason for the SVC status change. |
This object is implemented as defined in the corresponding MIB files. |
Description of MIB Tables
hwPWVcTable
This table is a PW configuration table. You can create and delete a PW by using this table.
For the switching PW, related objects of the switch can support the function of query according to the first VC ID.
In a PWE3 scenario, if the primary and secondary VCs are configured with the same VC ID, no operation can be performed in this table.
The indexes of this table are hwPwVcID and hwPwVcType.
OID |
Object Name |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.1 |
hwPWVcID |
Unsigned32(0 to 4294967295) |
Not-accessible |
The value of this object identifies the VC ID. The object is a decimal integer that ranges from 1 to 4294967295. The default value is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.2 |
hwPWVcType |
INTEGER{frameRelayDlciMartini(1),atmAal5SduVccTransport(2),atmTransparentCellTransport(3),vlan(4),ethernet(5),hdlc(6),ppp(7),cem(8),atmN2OneVccCellTransport(9),atmN2OneVpcCellTransport(10),ipLayer2Transport(11),atmOne2OneVccCellMode(12),atmOne2OneVpcCellMode(13),atmAal5PduVccTransport(14),frameRelayPortMode(15),cep(16),saE1oP(17),saT1oP(18),saE3oP(19),saT3oP(20),cESoPsnBasicMode(21),tDMoIPbasicMode(22),l2VpnCESoPSNTDMwithCAS(23),l2VpnTDMoIPTDMwithCAS(24),frameRelayDlci(25),ipInterworking(64),unknown(255)} |
Not-accessible |
This object indicates the encapsulation type of the PW. For details, see hwPwVcType. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.3 |
hwPWVcPeerAddrType |
INTEGER{unknown(0),ipv4(1),ipv6(2),ipv4z(3),ipv6z(4),dns(16)} |
Read-create |
The value of this object identifies the type of the peer IP address.
|
Currently, the maximum access is read-only. At present, this object supports only IPv4 addresses. Besides, if the protocol type of the PW is unknown, the value of this object is also unknown. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.4 |
hwPWVcPeerAddr |
OCTET STRING (SIZE (4)) |
Read-create |
This object indicates the peer IP address of the PW. If the type of hwPwVcPeerAddrType is unknown, the peer IP address of the PW is all 0s. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.5 |
hwPWVcStatus |
Integer{up(1),down(2),plugout(3),backup(4)} |
Read-only |
The value of this object identifies the PW status of the local node.
At present, this object does not support the plugout status. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.6 |
hwPWVcInboundLabel |
INTEGER (0..4294967295) |
Read-create |
The object indicates the value of the incoming label. The value is automatically allocated by the system. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.7 |
hwPWVcOutboundLabel |
INTEGER (0..4294967295) |
Read-create |
The object indicates the value of the outgoing label. The value is automatically allocated by the system. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.8 |
hwPWVcSwitchSign |
Integer{staticTostatic (1)ldpTostatic (2)ldpToldp (3)upe(4)} |
Read-only |
The value of this object identifies the type of the switching PW.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.9 |
hwPWVcSwitchID |
Unsigned32(0 to 4294967295) |
Read-create |
This object indicates the ID of the switching VC. The object is a decimal integer that ranges from 1 to 4294967295. The default value is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.10 |
hwPWVcSwitchPeerAddrType |
INTEGER{unknown(0),ipv4(1),ipv6(2),ipv4z(3),ipv6z(4),dns(16)} |
Read-create |
The value of this object identifies the peer IP address type of the switching PW.
|
Currently, the maximum access is read-only. At present, this object supports only IPv4 addresses. Besides, if the protocol type of the PW is unknown, the value of this object is also unknown. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.11 |
hwPWVcSwitchPeerAddr |
OCTET STRING (SIZE (4)) |
Read-create |
This object indicates the peer IP address of the switching PW. If the type of hwPwSwitchVcPeerAddrType is unknown, the peer IP address of the switching PW is all 0s. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.12 |
hwPWVcSwitchInboundLabel |
INTEGER (0..4294967295) |
Read-create |
This object indicates the incoming label value of the switching PW.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.13 |
hwPWVcSwitchOutboundLabel |
INTEGER (0..4294967295) |
Read-create |
This object indicates the outgoing label value of the switching PW.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.14 |
hwPWVcGroupID |
INTEGER (0..4294967295) |
Read-create |
This object indicates the ID of the VC group. |
At present, this object is not supported. The value is 0. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.15 |
hwPWVcIfIndex |
Integer32 (0..2147483647) |
Read-create |
This object indicates the index of the AC interface that is associated with the PW. The value 0 indicates that the index of the interface is invalid. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.16 |
hwPWVcAcStatus |
INTEGER { up(1), down(2), plugout(3), notify(4), notifyDown(5), downNotify(6) } |
Read-only |
The value of this object identifies the status of the AC interface. |
At present, this object does not support the plugout status. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.17 |
hwPWVcACOAMStatus |
Integer{up(1),down(2)} |
Read-only |
The value of this object identifies the protocol status of the AC interface. 1: up 2: down |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.18 |
hwPWVcMtu |
Integer32 |
Read-create |
This object indicates the MTU value of the AC interface on the local node that is associated with the PW. The object is a decimal integer that is 0 or ranges from 46 to 9600. The default MTU value is 1500. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.19 |
hwPWVcCtrlWord |
INTEGER { enable(1), disable(2) } |
Read-create |
The value of this object identifies the capability of the control word.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.20 |
hwPWVcVCCV |
BITS { ccCw(0), ccAlert(1), ccLabel(2), cvIcmpping(3), cvLspping(4), cvBfd(5), ccTtl(6) } |
Read-create |
This object indicates the optional VCCV capabilities of the PW. According to whether the control word is enabled, the value can be ccCw(0)|ccAlert(1)|cvLspping(4)|cvBfd(5) or ccAlert(1)|ccTtl(6)|cvLspping(4)|cvBfd(5). The default value is ccAlert(1)|ccTtl(6)|cvLspping(4)|cvBfd(5).
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.23 |
hwPWVcTnlPolicyName |
Octet String(size(0..39)) |
Read-create |
This object indicates the name of the tunnel policy. The name is a string of 0 to 19 characters. By default, the length of the name is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.26 |
hwPWVcTemplateName |
Octet String(size(0..19)) |
Read-create |
This object indicates the name of the PW module. The object is a case-sensitive string of 0 to 19 characters. If the value of the object is not specified, the default value is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.27 |
hwPWVcSecondary |
INTEGER{true(1),false(2)} |
Read-create |
The value of this object identifies whether the PW is a backup PW.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.28 |
hwPWVcUpTime |
INTEGER (0..4294967295) |
Read-only |
This object indicates the duration when the PW keeps Up for the last time, in seconds. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.29 |
hwPWOAMSync |
INTEGER{true(1),false(2)} |
Read-create |
The value of this object identifies the association between an AC and a PSN.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.30 |
hwPWVCForBfdIndex |
INTEGER (0..4294967295) |
Read-only |
This object indicates the index of BFD for PW. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.31 |
hwPWVcDelayTime |
INTEGER (0..4294967295) |
Read-create |
This object indicates the delay time of PW switching. The object is a decimal integer, expressed in seconds. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.32 |
hwPWVcReroutePolicy |
Integer{delay(1), immediately(2), never(3), none(4), err(5), invalid(6), immediatelySwitch(7)} |
Read-create |
The value of this object identifies the switching policy of a PW.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.33 |
hwPWVcResumeTime |
INTEGER (0..4294967295) |
Read-create |
This object indicates the delay time of PW switching after resumption. The object is a decimal integer, expressed in seconds. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.34 |
hwPWVcRerouteReason |
INTEGER{invalidReason(1),vcCreated(2),vcDeleted(3),ldpSessionDown(4),ldpSessionUp(5),receivedDifLabelOrMtu(6),receivedIntfParaMatching(7),receivedIntfParaUnMatched(8),receivedUnPassCbitCheck(9),receivedUnPassPwLoopCheck(10),receivedNewMapping(11),receivedNewMappingButRemoteVcDown(12),receivedWithdrawn(13),receivedLdpRelease(14),receivedLdpRequest(15),ldpGrEndProcessing(16),receivedRsvpMessage(17),interfaceUp(18),interfaceDown(19),interfaceEncapChanged(20),refresh(21),downloadAgain(22),tunnelUp(23),tunnelDown(24),receivedNewRlb(25),deletedRlb(26),vcCreatedOrTurnedToAnother(27),outInterInInvalidState(28),outInterInValidNow(29),ldpNotifiForward(30),ldpNotifiNotForward(31),pwRestart(32),downloadFtnAndIlmForEthTrunk(33),acOamFaultDetectDisable(34),remoteAcFault(35),remoteAcFaultResume(36),localAcFault(37),localAcFaultResume(38),remotePsnFault(39),remotePsnFaultResume(40),localPsnFault(41),localPsnFaultResume(42),bfdForPwStateChangeToDown(43),bfdForPwStateChangeToUp(44),bfdForPwStateChangeToAdminDown(45),bfdForPwDisable(46),manualSetEnable(47),manualSetDisable(48),delayTimeOut(49),resumeTimeOut(50),vrrpMaster(51),vrrpBackup(52),vrrpInit(53),vrrpDelete(54),vrrpTrack(55),undoVrrpTrack(56),lspPingTimeOut(57),vcDownWhenReceivedNewRLB(58),mtuMatched(59),mtuUnmatched(60),vsiShut(61),vsiResume(62),setAdminVSI(63),undosetAdminVSI(64),bvsiBindAc(65),bvsiUnbindAc(66),ivsiBindBVSI(67),ivsiUnbindBVSI(68),deletedVSI(69),reconstructFwdTable(70),mclagMaster(71),mclagBackup(72),adminPwUp(73),adminPwDown(74),vccvOk(75),vccvFailed(76),localIfnetOk(77),inVcLabelOk(78),localIfnetRelease(79),inVcLabelRelease(80),switchOverEnable(81),switchOverDisable(82),setBVSI(83),undoSetBVSI(84),shutdownBVSI(85),undoShutdownBVSI(86),notificationReceived(87),pwApsSwitch(88),routeUnreachable(89),routeReachable(90),aging(91),verification(92),tdmBitRateMatched(93),tdmBitRateUnmatched(94)} |
Read-only |
This object indicates the reason of PW switching. For details, see hwPwStateChangeReason. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.35 |
hwPWVcLastRerouteTime |
INTEGER (0..4294967295) |
Read-only |
This object indicates the time of the last switching of PW. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.36 |
hwPWVcManualSetFault |
INTEGER{true(1),false(2)} |
Read-create |
The value of this object identifies whether the fault flag is manually set.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.37 |
hwPWVcActive |
INTEGER{true(1),false(2)} |
Read-only |
The value of this object identifies whether the current PW is in the Active state.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.40 |
hwPWBFDDetectMultiplier |
Unsigned32(0|3-50) |
Read-create |
This object indicates the local BFD detection multiple. The value ranges from 3 to 50. If the BFD detect function is not enabled, the value is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.41 |
hwPWBFDMinReceiveInterval |
Unsigned32 (0 | 3..1000) |
Read-create |
This object indicates the interval for receiving BFD packets. The value ranges from 3 to 1000, in milliseconds. If the BFD detect function is not enabled, the value is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.42 |
hwPWBFDMinTransmitInterval |
Unsigned32 (0 | 3..1000) |
Read-create |
This object indicates the interval to send BFD packets. The value ranges from 3 to 1000, expressed in milliseconds. If the BFD detect function is not enabled, the value is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.43 |
hwPWDynamicBFDDetect |
INTEGER{true(1),false(2)} |
Read-create |
The value of this object identifies whether the dynamic BFD for PW is supported.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.44 |
hwPWBFDRemoteVcID |
Unsigned32(0 to 4294967295) |
Read-create |
In the case of multiple segments, this object indicates the peer VC ID. The value ranges from 1 to 4294967295. The default value is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.45 |
HwPWEthOamType |
Integer{ethOam1ag(1), ethOam3ah(2), noEthOamCfg(3)} |
Read-create |
The value of this object identifies the type of the associated Ethernet OAM. The object has the following values:
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.47 |
hwPWVcUpStartTime |
DisplayString (SIZE (0..63)) |
Read-only |
This object indicates the time when the PW returns to the Up state last time. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.48 |
hwPWVcUpSumTime |
INTEGER (0..4294967295) |
Read-only |
This object indicates the accumulated time when the VC is Up, in seconds. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.49 |
hwPWVcIfName |
DisplayString (SIZE (0..63)) |
Read-only |
Indicates the name of a VC interface. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.51 |
hwPWVcRowStatus |
INTEGER{active(1),notInService(2),notReady(3),createAndGo(4),createAndWait(5),destroy(6)} |
Read-create |
This object indicates the row status of this table. Restriction:
After creating this table, you are unable to modify the configuration. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.57 |
hwPWVcSwitchTnlPolicyName |
OCTET STRING (SIZE (0..19)) |
Read-create |
Indicates the switch tunnel policy name used. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.61 |
hwPWVcRawOrTagged |
INTEGER { raw(1), tagged(2), rawTagNotConfiged(3) } |
Read-only |
Specifies whether the VLAN tag of the VC entry is attached or stripped. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.62 |
hwPWVcInterworkingType |
INTEGER { ipInterWorking(1), ipLayer2(2), ipUnknown(3) } |
Read-only |
Specifies the interworking type of the VC entry. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.69 |
hwPWVcTrigger |
INTEGER{true(1),false(2)} |
Read-create |
Specifies whether the PW remote interface shutdown or not. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.70 |
hwPWVcEnableACOAM |
INTEGER{enabled(1),disabled(2)} |
Read-create |
Specifies whether ACOAM detection and notification are all enabled or not. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.74 |
hwPWVcBfdParaFromPWT |
INTEGER { liOrMib(1), pwTemplate(2), unknown(3) } |
Read-only |
This object indicates the configuration of the BFD parameters managed through command line or PW template. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.80 |
hwPwVcSwitchAdminPwIfIndex |
Integer32 (0..2147483647) |
Read-create |
This object indicates the index of the interface on which the administrator PW resides after it is being tracked by the switch PW. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.81 |
hwPwVcSwitchAdminPwLinkStatus |
INTEGER { up(1), down(2), unknown(3) } |
Read-only |
This object indicates the status of the administrator PW after it is being tracked by the switch PW. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.98 |
hwPwVcSwitchCwTrans |
INTEGER{true(1),false(2)} |
Read-create |
This object indicates whether the SPE support Control Word Transparent or not, and the default value is false. |
This object is implemented as defined in the corresponding MIB files. |
Creation Restriction
None.
Modification Restriction
The entries in this table can be modified.
- The hwPWOAMSync, hwPWVcReroutePolicy, hwPWVcManualSetFault, hwPWDynamicBFDDetect, and hwPWVcTrigger support the modification of single-segment PWE3 only.
- The hwPWVcSwitchCir and hwPWVcSwitchVrID support the modification of multi-segment PWE3 only.
- The hwPWVcPeerAddr, hwPWVcSwitchPeerAddr, hwPWVcDelayTime, hwPWVcResumeTime, hwPWVcVrIfIndex, hwPWBFDDetectMultiplier, hwPWBFDMinReceiveInterval, hwPWBFDMinTransmitInterval, hwPWBFDRemoteVcID, hwPWEthOamType, hwPWVcCfmMaName, hwPWVcCfmMdName, hwPWVcEnableACOAM, and hwPWVcSwitchVrIfIndex cannot be modified independently. Instead, it takes affect only after cooperation with another modification.
Deletion Restriction
None.
Access Restriction
None.
hwPWVcTnlTable
This table is used to query the tunnel index of a PW.
In a PWE3 scenario, if the primary and secondary VCs are configured with the same VC ID, no operation can be performed in this table.
The indexes of this table are hwPwVcID, hwPwVcType, and hwPwVcTnlIndex.
OID |
Object Name |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.1.2.1.1 |
hwPWVcTnlIndex |
INTEGER (0..4294967295) |
Not-accessible |
This object indicates the tunnel index of PW. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.2.1.2 |
hwPWVcTnlType |
INTEGER { lsp(1), gre(2), ipsec(3), crLsp(4) } |
Read-only |
This object indicates the tunnel type.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.2.1.3 |
hwPWTnlForBfdIndex |
INTEGER (0..4294967295) |
Read-only |
This object indicates the index of BFD for LSP. |
This object is implemented as defined in the corresponding MIB files. |
Creation Restriction
No entry can be created in this table.
Modification Restriction
The entries in this table cannot be modified.
Deletion Restriction
The entries in this table cannot be deleted.
Access Restriction
The entries in this table can be queried only when detecting PW through BFD is configured.
hwPWRemoteVcTable
This table is used to query the peer information of a VC. If the switching VC exists, the peer information of the switching VC can be queried.
In a PWE3 scenario, if the primary and secondary VCs are configured with the same VC ID, no operation can be performed in this table.
The indexes of this table are hwPwVcID and hwPwVcType.
OID |
Object Name |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.1.4.1.1 |
hwPWRemoteVcID |
INTEGER (0..4294967295) |
Read-only |
This object indicates the VC ID of the remote PW. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.4.1.2 |
hwPWRemoteVcType |
INTEGER{frameRelayDlciMartini(1),atmAal5SduVccTransport(2),atmTransparentCellTransport(3),vlan(4),ethernet(5),hdlc(6),ppp(7),cem(8),atmN2OneVccCellTransport(9),atmN2OneVpcCellTransport(10),ipLayer2Transport(11),atmOne2OneVccCellMode(12),atmOne2OneVpcCellMode(13),atmAal5PduVccTransport(14),frameRelayPortMode(15),cep(16),saE1oP(17),saT1oP(18),saE3oP(19),saT3oP(20),cESoPsnBasicMode(21),tDMoIPbasicMode(22),l2VpnCESoPSNTDMwithCAS(23),l2VpnTDMoIPTDMwithCAS(24),frameRelayDlci(25),ipInterworking(64),unknown(255)} |
Read-only |
This object indicates the encapsulation type of the remote PW. For details, see hwPwVcType. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.4.1.3 |
hwPWRemoteVcStatus |
Integer{up(1),down(2),plugout(3)} |
Read-only |
The value of this object identifies the status of the remote PW.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.4.1.4 |
hwPWRemoteVcGroupID |
INTEGER (0..4294967295) |
Read-only |
This object indicates the VC Group ID of the remote PW. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.4.1.5 |
hwPWRemoteVcMtu |
Unsigned32 (0 | 46..9600) |
Read-only |
The value of this object identifies the MTU value of remote PW. The value ranges from 46 to 9600. The default MTU value is 1500. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.4.1.6 |
hwPWRemoteVcCtrlword |
INTEGER { enable(1), disable(2) } |
Read-only |
The value of this object identifies the control word capability of remote PW.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.1.4.1.8 |
hwPWRemoteVcNotif |
INTEGER{true(1),false(2)} |
Read-only |
The value of this object identifies whether the remote PW supports the Notification packet.
|
This object is implemented as defined in the corresponding MIB files. |
Creation Restriction
No entry can be created in this table.
Modification Restriction
The entries in this table cannot be modified.
Deletion Restriction
The entries in this table cannot be deleted.
Access Restriction
The entries in this table can be read only when a remote VC exists and the signaling from the VC is received.
hwSvcTable
This table is an SVC configuration table. You can create and delete an SVC by using the table. Now the entries in this table can be queried only.
The index of this table is hwSvcIfIndex.
OID |
Object Name |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.1 |
hwSvcIfIndex |
Integer32 (0..2147483647) |
Not-accessible |
This object indicates the index of the AC interface associated with the SVC. The value 0 indicates that the index of the interface is invalid. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.2 |
hwSvcID |
Unsigned32(0~4294967295) |
Read-create |
This object indicates the VC ID. The value is a decimal integer that ranges from 0 to 4294967295. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.3 |
hwSvcType |
INTEGER{frameRelayDlciMartini(1),atmAal5SduVccTransport(2),atmTransparentCellTransport(3),vlan(4),ethernet(5),hdlc(6),ppp(7),cem(8),atmN2OneVccCellTransport(9),atmN2OneVpcCellTransport(10),ipLayer2Transport(11),atmOne2OneVccCellMode(12),atmOne2OneVpcCellMode(13),atmAal5PduVccTransport(14),frameRelayPortMode(15),cep(16),saE1oP(17),saT1oP(18),saE3oP(19),saT3oP(20),cESoPsnBasicMode(21),tDMoIPbasicMode(22),l2VpnCESoPSNTDMwithCAS(23),l2VpnTDMoIPTDMwithCAS(24),frameRelayDlci(25),ipInterworking(64),unknown(255)} |
Read-create |
This object indicates the encapsulation type of the PW. For details, see hwPwVcType. |
Currently, the maximum access is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.4 |
hwSvcPeerAddrType |
INTEGER{unknown(0),ipv4(1),ipv6(2),ipv4z(3),ipv6z(4),dns(16)} |
Read-create |
The value of this object identifies the type of the peer IP address.
|
Currently, the maximum access is read-only; At present, this object supports only IPv4 addresses. Besides, if the protocol type of the PW is unknown, the value of this object is also unknown. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.5 |
hwSvcPeerAddr |
OCTET STRING (SIZE (4)) |
Read-create |
This object indicates the peer IP address of the SVC. If the type of hwSvcPeerAddrType is unknown, the peer IP address of the SVC is all 0s. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.6 |
hwSvcStatus |
Integer{up(1),down(2),plugout(3)} |
Read-only |
The value of this object identifies the SVC status of the local node.
|
At present, this object does not support the plugout status. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.7 |
hwSvcInboundLabel |
INTEGER (0..4294967295) |
Read-create |
This object indicates the value of the inbound label for the SVC. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.8 |
hwSvcOutboundLabel |
INTEGER (0..4294967295) |
Read-create |
This object indicates the value of the outbound label for the SVC. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.10 |
hwSvcAcStatus |
Integer{up(1),down(2),plugout(3)} |
Read-only |
The value of this object identifies the physical status of the AC.
|
At present, this object does not support the plugout status. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.11 |
hwSvcACOAMStatus |
Integer{up(1),down(2)} |
Read-only |
The value of this object identifies the protocol status of the AC interface.
|
At present, this object is not supported. The query result is always down(2). |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.13 |
hwSvcCtrlWord |
INTEGER { enable(1), disable(2) } |
Read-create |
The value of this object identifies the capability of control word.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.14 |
hwSvcVCCV |
BITS { ccCw(0), ccAlert(1), ccLabel(2), cvIcmpping(3), cvLspping(4), cvBfd(5) } |
Read-create |
Indicates the optional VCCV capabilities of the SVC. The default value is ccAlert(1), cvLspping(4), and cvBfd(5). |
Currently, the maximum access is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.16 |
hwSvcMaxAtmCells |
Unsigned32 (0..28) |
Read-create |
This object indicates the maximum cell number supported by the SVC when the SVC type is ATM. The object is a decimal integer ranging from 0 to 28. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.17 |
hwSvcTnlPolicyName |
Octet String(size(0..39)) |
Read-create |
This object indicates the name of the tunnel policy. The name is a string of 1 to 19 characters. By default, the length of the name is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.19 |
hwSvcPWTemplateName |
Octet String(size(0..19)) |
Read-create |
This object indicates the name of the PW template. The name is a case-sensitive string of 0 to 19 characters. If not specified, the default value of the object is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.20 |
hwSvcUpTime |
INTEGER (0..4294967295) |
Read-only |
This object indicates the duration when the SVC keeps Up for the last time, in seconds. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.21 |
hwSvcOAMSync |
INTEGER{true(1),false(2)} |
Read-only |
The value of this object identifies the association between an AC and a PSN.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.22 |
hwSvcForBfdIndex |
INTEGER (0..4294967295) |
Read-only |
This object indicates the SVC PW index detected by BFD. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.31 |
hwSvcUpStartTime |
DisplayString (SIZE (0..63)) |
Read-only |
This object indicates the time when the PW returns to the Up state last time. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.32 |
hwSvcUpSumTime |
INTEGER (0..4294967295) |
Read-only |
This object indicates the accumulated time when the SVC is Up, in seconds. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.38 |
hwSvcRawOrTagged |
INTEGER { raw(1), tagged(2), rawTagNotConfiged(3) } |
Read-create |
Specifies whether the VLAN tag of the SVC entry is attached or stripped. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.39 |
hwSvcInterworkingType |
INTEGER { ipInterWorking(1), ipLayer2(2), ipUnknown(3) } |
Read-create |
Specifies the interworking type of the SVC entry. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.51 |
hwSvcRowStatus |
INTEGER{active(1),notInService(2),notReady(3),createAndGo(4),createAndWait(5),destroy(6)} |
Read-create |
This object indicates the row status of this table. Restriction:
|
This object is implemented as defined in the corresponding MIB files. |
Creation Restriction
None
Modification Restriction
None
Deletion Restriction
None
Access Restriction
None
hwSvcTnlTable
This table is used to query the tunnel index of an SVC.
The index of this table is hwSvcTnlIndex.
OID |
Object Name |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.3.2.1.1 |
hwSvcTnlIndex |
INTEGER (0..4294967295) |
Not-accessible |
This object indicates the tunnel index of SVC. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.2.1.2 |
hwSvcTnlType |
INTEGER { lsp(1), gre(2), ipsec(3), crLsp(4) } |
Read-only |
This object indicates the tunnel type of the SVC. |
This object is implemented as defined in the corresponding MIB files. |
Creation Restriction
No entry can be created in this table.
Modification Restriction
The entries in this table cannot be modified.
Deletion Restriction
The entries in this table cannot be deleted.
Access Restriction
The entries in this table can be queried only when detecting PW through BFD is configured.
hwSvcExtTable
This table is an SVC extended configuration table. It allows you to query, create, and delete SVCs. Currently, only the query function is available.
The indexes of this table are hwSvcExtIfIndex and hwSvcExtPWType.
OID |
Object Name |
Data Type |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.1 |
hwSvcExtIfIndex |
Integer32 (0..2147483647) |
Not-accessible |
This object indicates the index of an interface associated with a PW. |
This object is implemented as defined in the corresponding MIB file. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.2 |
hwSvcExtPWType |
INTEGER{main(1),secondary(2),bypass(3)} |
not-accessible |
This object indicates the SVC type. |
This object is implemented as defined in the corresponding MIB file. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.3 |
hwSvcExtID |
INTEGER (0..4294967295) |
Read-create |
The value of this object identifies the VC ID. |
The maximum access to this object is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.4 |
hwSvcExtType |
INTEGER{frameRelayDlciMartini(1),atmAal5SduVccTransport(2),atmTransparentCellTransport(3),vlan(4),ethernet(5),hdlc(6),ppp(7),cem(8),atmN2OneVccCellTransport(9),atmN2OneVpcCellTransport(10),ipLayer2Transport(11),atmOne2OneVccCellMode(12),atmOne2OneVpcCellMode(13),atmAal5PduVccTransport(14),frameRelayPortMode(15),cep(16),saE1oP(17),saT1oP(18),saE3oP(19),saT3oP(20),cESoPsnBasicMode(21),tDMoIPbasicMode(22),l2VpnCESoPSNTDMwithCAS(23),l2VpnTDMoIPTDMwithCAS(24),frameRelayDlci(25),ipInterworking(64),unknown(255)} |
Read-create |
This object indicates the encapsulation type of a PW. For specific encapsulation types, see hwPwVcType. |
The maximum access to this object is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.5 |
hwSvcExtPeerAddrType |
INTEGER{unknown(0),ipv4(1),ipv6(2),ipv4z(3),ipv6z(4),dns(16)} |
Read-create |
This object indicates the peer IP address type. |
The maximum access to this object is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.6 |
hwSvcExtPeerAddr |
OCTET STRING (SIZE (4)) |
Read-create |
This object indicates the peer IP address of the SVC. If the type of hwSvcPeerAddrType is unknown, the peer IP address of the SVC is all 0s. |
The maximum access to this object is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.7 |
hwSvcExtStatus |
Integer {
} |
Read-only |
The value of this object identifies the SVC status of the local node:
|
Currently, Plugout is not supported. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.8 |
hwSvcExtInboundLabel |
INTEGER (0..4294967295) |
Read-create |
The value of this object identifies the in-label for the SVC. |
The maximum access to this object is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.9 |
hwSvcExtOutboundLabel |
INTEGER (0..4294967295) |
Read-create |
The value of this object identifies the out-label for the SVC. |
The maximum access to this object is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.10 |
hwSvcExtAcStatus |
INTEGER: {
} |
Read-only |
This object indicates the physical status of an AC interface:
|
Currently, Plugout is not supported. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.11 |
hwSvcExtACOAMStatus |
INTEGER: {
} |
Read-only |
The value of this object identifies the protocol status of an AC interface:
|
This object is unavailable Currently. The query result is down(2). |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.12 |
hwSvcExtCtrlWord |
INTEGER { enable(1), disable(2) } |
Read-create |
This object indicates the control word capability:
|
The maximum access to this object is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.13 |
hwSvcExtVCCV |
BITS: {
} |
Read-create |
This object indicates optional VCCV capabilities. By default, the values are ccAlert(1), cvLspping(4), and cvBfd(5). |
The maximum access to this object is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.14 |
hwSvcExtMaxAtmCells |
Unsigned32 (0..28) |
Read-create |
The value of this object identifies the maximum cell number supported by the SVC when the SVC type is ATM. The value is a decimal integer ranging from 0 to 28. |
The maximum access to this object is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.15 |
hwSvcExtTnlPolicyName |
OCTET STRING (SIZE (0..39)) |
Read-create |
This object indicates the name of a tunnel policy. If not specified, the default tunnel policy name length is 0. |
The maximum access to this object is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.16 |
hwSvcExtPWTemplateName |
OCTET STRING (SIZE (0..19)) |
Read-create |
This object indicates the name of a PW template. If not specified, the default value is 0. |
The maximum access to this object is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.17 |
hwSvcExtUpTime |
INTEGER (0..4294967295) |
Read-only |
The value of this object identifies the latest total Up time of the SVC. |
This object is implemented as defined in the corresponding MIB file. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.19 |
hwSvcExtForBfdIndex |
INTEGER (0..4294967295) |
Read-only |
The value of this object identifies the index of the SVC PW detected by BFD. |
This object is implemented as defined in the corresponding MIB file. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.27 |
hwSvcExtUpStartTime |
DisplayString (SIZE (0..63)) |
Read-only |
This object indicates the time when the PW was restored the last time. |
This object is implemented as defined in the corresponding MIB file. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.28 |
hwSvcExtUpSumTime |
INTEGER (0..4294967295) |
Read-only |
The value of this object identifies the total Up time of the SVC, in seconds. |
This object is implemented as defined in the corresponding MIB file. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.34 |
hwSvcExtRawOrTagged |
INTEGER: {
} |
Read-create |
The value of this object identifies whether the tagged flag is carried. |
The maximum access to this object is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.35 |
hwSvcExtInterworkingType |
INTEGER: {
} |
Read-create |
The value of this object identifies whether interworking is supported. |
The maximum access to this object is read-only. |
1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.36 |
hwSvcExtRowStatus |
INTEGER{active(1),notInService(2),notReady(3),createAndGo(4),createAndWait(5),destroy(6)} |
Read-create |
This object indicates the row status. |
The maximum access to this object is read-only. |
Creation Restriction
None
Modification Restriction
None
Deletion Restriction
None
Access Restriction
None
hwPWTemplateTable
This table is a PW template configuration table. You can create and delete a PW template by using this table. Now the entries in this table can be queried only.
The index of this table is hwPwTemplateName.
OID |
Object Name |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.5.1.1 |
hwPWTemplateName |
Octet String(size(0..19)) |
Not-accessible |
This object indicates the name of the PW template. The name is a case-sensitive string of 0 to 19 characters. If not specified, the default value of the object is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.5.1.2 |
hwPWTemplatePeerAddrType |
INTEGER{unknown(0),ipv4(1),ipv6(2),ipv4z(3),ipv6z(4),dns(16)} |
Read-create |
The value of this object specifies the type of the peer IP address.
|
Currently, the maximum access is read-only; At present, this object supports only IPv4 addresses. Besides, if the protocol type of the PW is unknown, the value of this object is also unknown. |
1.3.6.1.4.1.2011.5.25.119.4.1.5.1.3 |
hwPWTemplatePeerAddr |
OCTET STRING (SIZE (4)) |
Read-create |
The object indicates the peer IP address of the PW. If the value is all 0s, the specified peer IP address of the PW is deleted from the PW template. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.5.1.4 |
hwPWTemplateCtrlword |
INTEGER { enable(1), disable(2) } |
Read-create |
The value of this object identifies the capability of control word.
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.5.1.5 |
hwPWTemplateVCCV |
BITS{ccCw(0),ccAlert(1),ccLabel(2),cvIcmpping(3),cvLspping(4),cvBfd(5),ccTtl(6)} |
Read-create |
This object indicates the optional VCCV capabilities of the PW template. According to whether the control word is enabled, the value can be ccCw(0)|ccAlert(1)|ccTtl(6)|cvLspping(4)|cvBfd(5) or ccAlert(1)|ccTtl(6)|cvLspping(4)|cvBfd(5). The default value is ccAlert(1)|ccTtl(6)|cvLspping(4)|cvBfd(5).
|
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.5.1.8 |
hwPWTemplateTnlPolicyName |
Octet String(size(0..39)) |
Read-create |
This object indicates the name of the tunnel policy. The name is a string of 0 to 19 characters. By default, the length of the name is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.5.1.11 |
hwPWTemplateBfdDetectMultiplier |
Unsigned32(0|3–50) |
Read-create |
This object indicates the local BFD detection multiple. The value of the object ranges from 3 to 50. When the BFD detect function is not enabled in the PW template, the value of the object is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.5.1.12 |
hwPWTemplateBfdMinReceiveInterval |
Unsigned32(0|10~1000) |
Read-create |
This object indicates the interval to receive BFD packets. The value of the object ranges from 10 to 1000, expressed in milliseconds. When the BFD detect function is not enabled in the PW template, the value of the object is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.5.1.13 |
hwPWTemplateBfdMinTransmitInterval |
Unsigned32(0|10~1000) |
Read-create |
This object indicates the interval to send BFD packets. The value of the object ranges from 10 to 1000, expressed in milliseconds. When the BFD detect function is not enabled in the PW template, the value of the object is 0. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.5.1.14 |
hwPWTemplateDynamicBfdDetect |
INTEGER{true(1),false(2)} |
Read-create |
The value of this object identifies whether the dynamic BFD for PW is supported. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.5.1.19 |
hwPWTemplatePwIdleCode |
Unsigned32 (0..255 | 65535) |
Read-create |
This object indicates the value of an idle code. The value is a hexadecimal number ranging from 0x00 to 0xFF. The default value is 0xFF and the invalid value is 0xFFFF. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.119.4.1.5.1.51 |
hwPWTemplateRowStatus |
INTEGER{active(1),notInService(2),notReady(3),createAndGo(4),createAndWait(5),destroy(6)} |
Read-create |
This object indicates the row status of this table. Restriction: To create this table, you must adopt the CreatAndGo processing mode, rather than the CreatAndWait processing mode. |
This object is implemented as defined in the corresponding MIB files. |
Creation Restriction
None.
Modification Restriction
The entries in this table can be modified.
- The hwPWTemplateBFDDetectMultiplier, hwPWTemplateBFDMinReceiveInterval, and hwPWTemplateBFDMinTransmitInterval must be used together with the hwPWTemplateDynamicBFDDetect.
- The hwPWTemplatePwCCSeqEnable can be used only after the hwPWTemplateCtrlword is configured.
Deletion Restriction
None.
Access Restriction
None.
Description of Alarm Objects
hwPwVcSwitchWtoP
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.2.1 |
hwPwVcSwitchWtoP |
|
The PW status turns from working to protect. For details, see hwPwStateChangeReason. |
This object is implemented as defined in the corresponding MIB files. |
hwPwVcSwitchPtoW
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.2.2 |
hwPWVcSwitchPtoW |
|
The PW status turns from protect to working. For details, see hwPwStateChangeReason. |
This object is implemented as defined in the corresponding MIB files. |
hwPWVcDeleted
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.2.5 |
hwPWVcDeleted |
|
This object indicates a PW deletion alarm. |
This object is implemented as defined in the corresponding MIB file. |
hwPwVcDown
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.2.3 |
hwPwVcDown |
|
The alarm is generated when the active PW or the backup PW turns Down. For details, see hwPwStateChangeReason. |
This object is implemented as defined in the corresponding MIB files. |
hwPwVcUp
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.2.4 |
hwPwVcUp |
|
The alarm is generated when the active PW or the backup PW turns Up. For details, see hwPwStateChangeReason. |
This object is implemented as defined in the corresponding MIB files. |
hwPWVcBackup
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.2.6 |
hwPWVcBackup |
|
An alarm is generated when the PW status changes to Backup. For details, see hwPwStateChangeReason. |
This object is implemented as defined in the corresponding MIB files. |
hwSvcDeleted
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.4.5 |
hwSvcDeleted |
|
This object indicates an SVC deletion alarm. |
This object is implemented as defined in the corresponding MIB file. |
hwSvcDown
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.4.3 |
hwSvcDown |
|
The alarm is generated when the SVC turns Down. For details, see hwPwStateChangeReason. |
This object is implemented as defined in the corresponding MIB files. |
hwSvcUp
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.4.4 |
hwSvcUp |
|
The alarm is generated when the SVC turns Up. For details, see hwPwStateChangeReason. |
This object is implemented as defined in the corresponding MIB files. |
hwSvcSwitchWtoP
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.4.1 |
hwSvcSwitchWtoP |
|
The status of a PW changes from Working to Protect. For details, see hwPwStateChangeReason. |
This object is implemented as defined in the corresponding MIB file. |
hwSvcSwitchPtoW
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.4.2 |
hwSvcSwitchPtoW |
|
The status of a PW changes from Protect to Working. For details, see hwPwStateChangeReason. |
This object is implemented as defined in the corresponding MIB file. |
hwPWVcStatusChange
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.2.9 |
hwPWVcStatusChange |
|
This object indicates the VC status change. |
This object is implemented as defined in the corresponding MIB file. |
hwVpwsPwRedundancyDegraded
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.2.10 |
hwVpwsPwRedundancyDegraded |
|
VLL FRR protection degraded. |
This object is implemented as defined in the corresponding MIB file. |
hwVpwsPwRedundancyDegradedClear
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.2.11 |
hwVpwsPwRedundancyDegradedClear |
|
The VLL FRR protection degrade alarm was cleared. |
This object is implemented as defined in the corresponding MIB file. |
Appendix
hwPwStateChangeReason
The structure of hwPwStateChangeReason is as follows:
{
Invalid reason type (1)
VC Created (2)
VC Deleted (3)
LDP Session Down (4)
LDP Session Up (5)
LDP Same Mapping Received with different label or MTU (6)
LDP Same Mapping Received Interface Parameter matching (7)
LDP Mapping Received Interface Parameter UnMatched(8)
LDP Mapping Received UnPass CBit Check(9)
LDP Mapping Received UnPass PW Loop Check(10)
LDP New Mapping Received (11)
LDP New Mapping Received but Remote VC Down(12)
LDP Withdrawn Received (13)
LDP Release Received (14)
LDP Request Received (15)
LDP GR End processing (16)
RSVP message received (17)
Interface Up (18)
Interface Down (19)
Interface encapsulation changed (20)
Refresh (21)
Download Again (22)
Tunnel Up (23)
Tunnel Down (24)
VC state change when New RLB Received (25)
RLB Deleted (26)
VC created or turned to another remote CE (27)
Out Interface in Invalid state (28)
Out Interface in Valid now (29)
LDP Notification Forwarding (30)
LDP Notification Not-Forwarding (31)
PW Restart (32)
Download FTN&ILM for EthernetTrunk(33)
AC OAM Fault Detect Disable(34)
Remote AC Fault(35)
Remote AC Fault Resume(36)
Local AC Fault(37)
Local AC Fault Resume(38)
Remote PSN Fault(39)
Remote PSN Fault Resume(40)
Local PSN Fault(41)
Local PSN Fault Resume(42)
BFD for PW State Change to:Down(43)
BFD for PW State Change to:Up(44)
BFD for PW State Change to:Admin Down(45)
BFD for PW Disable(46)
Manual Set Enable(47)
Manual Set Disable(48)
Delay Time Out(49)
Resume Time Out(50)
VRRP Master(51)
VRRP Backup(52)
VRRP Init(53)
VRRP Delete(54)
Track VRRP(55)
Undo track VRRP(56)
LspPingTimeOut(57)
VCStateDownwhenNewRLBwasReceived(58)
MTUMatched(59)
MTUUnmatched(60)
VSIwasshuted(61)
VSIwasresumed(62)
SetAdminVSI(63)
UndosetAdminVSI(64)
BVSIBindAC(65)
BVSIUnbindAC(66)
IVSIBindBVSI(67)
IVSIUnbindBVSI(68)
DeletedVSI(69)
ReconstructFWDTable(70)
MCLAGMaster(71)
MCLAGBackup(72)
AdminPWUp(73)
AdminPWDown(74)
VCCVOK(75)
VCCVFailed(76)
LocalifnetOK(77)
InvclabelOK(78)
LocalifnetRelease(79)
InvclabelRelease(80)
SwitchoverEnable(81)
SwitchoverDisable(82)
SetBVSI(83)
undoSetBVSI(84)
ShutdownBVSI(85)
UndoShutdownBVSI(86)
NotificationReceived(87)
PWAPSSwitch(88)
routeUnreachable(89)
routeReachable(90)
aging(91)
verification(92)
tdmBitRateMatched(93)
tdmBitRateUnmatched(94)
}
hwPwVcType
The structure of hwPwVcType is as follows:
{
Frame Relay DLCI ( Martini Mode ) (1)
ATM AAL5 SDU VCC transport (2)
ATM transparent cell transport (3)
Ethernet Tagged Mode (4)
Ethernet (5)
HDLC (6)
PPP (7)
SONET/SDH Circuit Emulation Service Over MPLS (CEM) (8)
ATM n-to-one VCC cell transport (9)
ATM n-to-one VPC cell transport (10)
IP Layer2 Transport (11)
ATM one-to-one VCC Cell Mode (12)
ATM one-to-one VPC Cell Mode (13)
ATM AAL5 PDU VCC transport (14)
Frame-Relay Port mode (15)
SONET/SDH Circuit Emulation over Packet (CEP) (16)
Structure-agnostic E1 over Packet (SAE1oP) (17)
Structure-agnostic T1 (DS1) over Packet (SAT1oP) (18)
Structure-agnostic E3 over Packet (SAE3oP) (19)
Structure-agnostic T3 (DS3) over Packet (SAT3oP) (20)
CESoPSN basic mode (21)
TDMoIP basic mode (22)
CESoPSN TDM with CAS (23)
TDMoIP TDM with CAS (24)
Frame Relay DLCI (25)
IP-interworking (64)