HUAWEI-VBST-MIB
Functions Overview
Huawei defines the HUAWEI-VBST-MIB. VBST is a Huawei proprietary link management protocol that blocks redundant links on a Layer 2 network and trims the network to be tree-shaped to eliminate loops.
Root directory:
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).huawei(2011).huaweiMgmt(5).hwDatacomm(25).hwVbstMib(323)
Description of Single Objects
hwVbstMaxPVNum
OID |
Object Name |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.323.1.2 |
hwVbstMaxPVNum |
Integer32 |
accessible-for-notify |
The maximum number of the PV quantity of the interface supported by the switch. |
This object is implemented as defined in the corresponding MIB files. |
hwVbstVlanNum
OID |
Object Name |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.323.1.4 |
hwVbstVlanNum |
Integer32 |
accessible-for-notify |
The number of VLANs that do not participate in calculation in the VBST BPDUs received by the interface. |
This object is implemented as defined in the corresponding MIB files. |
hwVbstTrapVlan
OID |
Object Name |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.323.1.5 |
hwVbstTrapVlan |
OCTET STRING |
accessible-for-notify |
The list of VLANs that do not participate in calculation in the VBST BPDUs received by the interface. |
This object is implemented as defined in the corresponding MIB files. |
hwVbstTrapPort
OID |
Object Name |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.323.1.6 |
hwVbstTrapPort |
OCTET STRING |
accessible-for-notify |
The list of interfaces where the received VBST BPDUs contain the VLANs that do not participate in calculation. |
This object is implemented as defined in the corresponding MIB files. |
hwVbstMaxTrunkPVNum
OID |
Object Name |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.323.1.7 |
hwVbstMaxTrunkPVNum |
Integer32 |
accessible-for-notify |
The maximum number of the PV quantity of the Eth-Trunk interface supported by the switch. |
This object is implemented as defined in the corresponding MIB files. |
hwVbstConflictDescription
OID |
Object Name |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.323.1.8 |
hwVbstConflictDescription |
OctetString |
accessible-for-notify |
The specific cause of the Eth-Trunk configuration conflict with the remote observing port configuration. |
This object is implemented as defined in the corresponding MIB files. |
Description of Alarm Objects
hwVbstPVNumExceeded
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.323.2.3 |
hwVbstPVNumExceeded |
entPhysicalName hwVbstMaxPVNum |
The number of interfaces and VLANs participating in VBST calculation exceeded the maximum number of interfaces and VLANs allowed by VBST. |
This object is implemented as defined in the corresponding MIB files. |
hwVbstPVNumResumed
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.323.2.4 |
hwVbstPVNumResumed |
entPhysicalName hwVbstMaxPVNum |
This alarm is triggered when the number of interfaces and VLANs participating in VBST calculation falls below the maximum number of interfaces and VLANs allowed by VBST. |
This object is implemented as defined in the corresponding MIB files. |
hwVbstTrapInvalidPV
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.323.2.7 |
hwVbstTrapInvalidPV |
hwVbstTrapVlanNum hwVbstTrapVlan hwVbstTrapPort |
The number of VLANs that do not participate in calculation in the VBST BPDUs received by the interface exceeds the threshold. |
This object is implemented as defined in the corresponding MIB files. |
hwVbstTrunkPVNumExceeded
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.323.2.8 |
hwVbstTrunkPVNumExceeded |
hwVbstMaxTrunkPVNum |
The PV quantity of the Eth-Trunk interface exceeds the maximum number supported by the switch. |
This object is implemented as defined in the corresponding MIB files. |
hwVbstTrunkPVNumResumed
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.323.2.9 |
hwVbstTrunkPVNumResumed |
hwVbstMaxTrunkPVNum |
The number of PVs of the Eth-Trunk is restored to be within the allowed range. |
This object is implemented as defined in the corresponding MIB files. |
hwVbstRspanCfgConflict
OID |
Object Name |
Bound Variable |
Description |
Implemented Specifications |
---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.323.2.10 |
hwVbstRspanCfgConflict |
hwVbstConflictDescription |
In VBST mode, the Eth-Trunk configuration conflicts with the remote observing port configuration. |
This object is implemented as defined in the corresponding MIB file. |