Configuring the Client Clock
Procedure
- Run system-view
The system view is displayed.
- Run ntp-service { max-sys-poll max-sys-poll-value | spike-offset spike-offset-value | sync-interval interval } *
The following are configured:
- The maximum polling interval. The default interval is 217s.
- The timestamp difference between packets sent by the clock server and received by the client. The default difference is 128 ms.
- The interval at which synchronization of the client clock occurs. The default interval is 600 seconds.
Only the S5720-EI, S5720-HI, S5730-HI, S5731-H, S5731-S, S5731S-H, S5731S-S, S5732-H, S6720-EI, S6720-HI, S6720S-EI, S6730-H, S6730S-H, S6730-S, and S6730S-S support max-sys-poll max-sys-poll-value and spike-offset spike-offset-value parameters.
- Run ntp-service max-distance max-distance-value
The maximum NTP synchronization distance is configured.
By default, The maximum NTP synchronization distance is 1 second.