4G LTE
- Components in dashed-line boxes are optional. To highlight the key points, the figure does not show all factory-installed components and cables.
- The SmartModule is installed on the SmartACU2000D-D-03 before delivery, and you do not need to perform any operations on the SmartModule. If the SmartACU2000D-D-01 needs to provide more RS485 ports, the SmartModule can be installed.
Position |
Component |
Recommended Model or Specifications |
Component Source |
Quantity |
|
---|---|---|---|---|---|
SACU |
(Optional) SmartModule |
SmartModule1000A01 |
Purchased from Huawei |
1 |
|
(Optional) 24 V power supply |
- |
1 |
|||
Fitting bags for the PoE module and CPE |
PoE module |
- |
1 |
||
PoE SPDa |
- |
1 |
|||
Outside the SACU and transformer station |
CPE |
- |
1 |
||
Transformer station |
MCB |
Recommended rated current: 32 A; number of poles: 2 |
Prepared by the customer |
1 |
|
Three-phase power switch |
Knife fuse switch |
When the rated AC voltage on the LV side of the transformer station is less than or equal to 500 V, the rated voltage of the knife fuse switch should be greater than or equal to 600 V. When the rated AC voltage on the LV side of the transformer station is greater than 500 V and less than or equal to 800 V, the rated voltage of the knife fuse switch should be greater than or equal to 800 V. Recommended rated current of the fuse: 32 A; rated current of the knife fuse switch box: ≥ 32 A; number of poles: 3 (three fuses for each knife fuse switch box) |
|
||
Note a: If the CPE model is EG860, a PoE SPD is required. |
- Components listed in the table need to be installed onsite.
- Models of the components inside the transformer station are specified by the transformer station vendor.
No. |
Cable |
Recommended Model or Specifications |
Cross-sectional Area Range of the Cable (Recommended Value) |
---|---|---|---|
1 |
Three-phase AC power cable |
|
|
3 |
Peripheral RS485 communications cable |
Computer cable (DJYP2VP2-22 2x2x1) or armored shielded twisted pair that can be used outdoors, as well as OT-M4 terminals |
|
4 |
Cabinet PE cable |
Outdoor copper cable and OT-M6 terminals |
|
5 |
Network cable from the PoE module or PoE SPD to the CPE |
20 m (65.62 ft) long network cable delivered with the Huawei CPE. If the cable is not long enough, prepare a Cat 5e outdoor shielded network cable with an outer diameter of less than 9 mm (0.35 in.) and internal resistance of less than or equal to 1.5 ohms/10 m (1.5 ohms/32.81 ft), as well as shielded RJ45 connectors. |
- |
6 |
Single-phase AC power cable |
|
|
7 |
(Optional) 24 V DC output power cable |
|
|