Technical Specifications
Item |
SmartACU2000D-D-01 |
SmartACU2000D-D-03 |
|
---|---|---|---|
Communications mode |
SFP/ETH/RS485/MBUS |
||
Number of MBUS routes |
1 |
2 |
|
MBUS input (AC) |
380–800 V; three-phase |
||
Number of PID routes |
1 |
2 |
|
PID input (AC) |
380–800 V; three-phase+FE |
||
Three-phase input power |
480 W (maximum) |
2 x 330 W (maximum) |
|
Single-phase operating voltagea |
AC input: 100–240 V |
||
Single-phase input power |
110 W (maximum) |
||
Frequency |
50 Hz/60 Hz |
||
Cable routing mode |
Routed in and out from the bottom |
||
Operation and maintenance mode |
Operated and maintained from the front |
||
Operating environment |
Indoor and outdoor |
||
Maximum operating altitude |
4000 m (13123.36 ft) |
||
Installation mode |
Installed on a support, pole, or wall |
||
Dimensions (H x W x D, including the mounting plate) |
770 mm x 880 mm x 369 mm (30.31 in. x 34.65 in. x 14.53 in.) |
||
Net weight (including firestop putty, screws, and the mounting plate) |
About 49 kg (108.03 lb) |
About 61 kg (134.48 lb) |
|
Enclosure ingress protection (IP) rating |
IP65/Type 3R |
||
Operating humidity |
4%–100% RH |
||
Operating temperature |
–40°C to +60°C (–40°F to +140°F) |
||
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
||
Note a: Supports a 24 V power module. DC input and output: 24–28 V DC; 70 W (maximum) |