No relevant resource is found in the selected language.
Your browser version is too early. Some functions of the website may be unavailable. To obtain better user experience, upgrade the browser to the latest version.
SmartACU2000D Smart Array Controller User Manual (With PID Modules)
This document describes the SmartACU2000D smart array control cabinet (with PID Modules), that is, the smart array control unit in terms of installation, cable connections, commissioning, and maintenance.
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document.
Note: Even the most advanced machine translation cannot match the quality of professional translators.
Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Powering Off the System
Powering Off the System
Turn off the single-phase power switch that controls the power supply from the remote transformer station to the SACU.
Turn off the three-phase power switch that controls the power supply from the remote transformer station to the SACU.
Turn off the QF03 single-phase input switch in the SACU.
Turn off the three-phase input switch in the SACU.
Turn off FU01 for the SmartACU2000D-D-01.
Turn off FU01 and FU02 for the SmartACU2000D-D-03.
Turn off the PID switch in the SACU.
Turn off QF01 for the SmartACU2000D-D-01.
Turn off QF01 and QF02 for the SmartACU2000D-D-03.