Installing an Atlas 500 AI edge station (Without Drive)
Procedure
- Install the cabinet mount brackets on the Atlas 500 AI edge station.
- Place the cabinet mount brackets on both sides of the Atlas 500 AI edge station and align the screw holes on the Atlas 500 AI edge station and the brackets.
- Tighten the screws to secure the cabinet mount brackets.
The package of the 19-inch cabinet mount brackets has six GB819-85_M4x8_H countersunk screws. Tighten the screws to 1.2 N·m.
Figure 5-9 Installing the 19-inch cabinet mount brackets on the Atlas 500 AI edge station - Secure the Atlas 500 AI edge station to the posts in the cabinet.
- Place the spring nuts on the back of the two posts in the cabinet.
- Put the M6 screws with spring washers from the front and tighten the screws to secure the Atlas 500 AI edge station.
The package of the 19-inch cabinet mount brackets has four M6 screws with spring washers. Tighten the screws to 2.0 N·m.
Figure 5-10 Securing the Atlas 500 AI edge station to the posts - Leave a clearance equal to the device height in the arrow direction for heat dissipation, as shown in Figure 5-11.
Do not stack anything on top of the device, which may block the heat sink fins.
- Connect external cables.
For details, see Connecting External Cables.
- Power on the Atlas 500 AI edge station.
For details, see Power-On Procedure.
Installing an Atlas 500 AI edge station (with Drive)
Procedure
- Install the cabinet mount brackets on the Atlas 500 AI edge station.
- Place the cabinet mount brackets on both sides of the Atlas 500 AI edge station and align the screw holes on the Atlas 500 AI edge station and the brackets.
- Tighten the screws to secure the cabinet mount brackets.
The package of the 19-inch cabinet mount brackets has six GB819-85_M4x8_H countersunk screws. Tighten the screws to 1.2 N·m.
Figure 5-12 Installing the 19-inch cabinet mount brackets on the Atlas 500 AI edge station - Secure the Atlas 500 AI edge station to the posts in the cabinet.
- Place the spring nuts on the back of the two posts in the cabinet.
- Put the M6 screws with spring washers from the front and tighten the screws to secure the Atlas 500 AI edge station.
The package of the 19-inch cabinet mount brackets has four M6 screws with spring washers. Tighten the screws to 2.0 N·m.
Figure 5-13 Securing the Atlas 500 AI edge station to the posts - Leave a clearance equal to the device height in the arrow direction for heat dissipation, as shown in Figure 5-14.
Do not stack anything on top of the device, which may block the heat sink fins.
- Connect external cables.
For details, see Connecting External Cables.
- Power on the Atlas 500 AI edge station.
For details, see Power-On Procedure.