Mainboard Cables
Left and Right Mounting Ear Cabling
No. |
Description |
Part No. |
---|---|---|
1 |
Signal cable for connecting the mainboard (J16) to the right mounting ear plate |
04052595 |
2 |
Signal cable for connecting the mainboard (J6) to the left mounting ear plate |
04080650-005 |
Power Cables of the Drive Backplane
No. |
Description |
Part No. |
---|---|---|
A |
Power cable from the mainboard (J99) to the drive backplane (J35) |
Three-in-one cables 04153040 |
B |
Power cable from the mainboard (J76) to the drive backplane (J34 or J1) |
|
C |
Power cable from the mainboard (J31) to the drive backplane (J1 or J34) |
High-Speed Cables of the Drive Backplane
No. |
Description |
Part No. |
---|---|---|
A |
LP Slimline cable of the data drive from the drive backplane (J31) to the mainboard (J204) |
Four-in-one cables (04052598) |
B |
LP Slimline cable from the side (SLIM A J304) of riser module 1 to the mainboard (J304) |
|
C |
LP Slimline cable of the data drive from the drive backplane (J7) to the mainboard (J004) |
|
D |
SAS HD cable of the system drive from the drive backplane (PORT A J4) to the mainboard (J73) |
Low-Speed Signal Cables of the Drive Backplane
No. |
Description |
Part No. |
---|---|---|
1 |
Low-speed signal cable from the drive backplane (J29) to the mainboard (J2079) |
04080651-006 |
SDI Card Cable (Installed on Riser Module 1)
No. |
Description |
Part No. |
---|---|---|
1 |
Power cable from the SDI card to riser module 1 |
04150448-004 |
2 |
LP Slimline cable from the SDI card to the side (SLIM A J304) of riser module 2 |
04052516-001 |
3 |
Serial cable from the SDI card to the mainboard (J24) |
04080791 |
Liquid Leakage Detection Cable on Mainboard
The mainboard is equipped with a group of leakage detection devices. Figure 3-9 shows the connection of the liquid leakage detection cables, and Table 3-8 lists the cable ends.
No. |
Description |
Part No. |
---|---|---|
1 |
Liquid leakage detection cable from the water outlet pipe to the liquid leakage detection board |
- |
2 |
Cable from the mainboard (J33) to the liquid leakage detection board |
04080584 |
3 |
Liquid leakage detection cable from the water inlet pipe to the liquid leakage detection board |
- |
Liquid Leakage Detection Cable on the NPU board
Each of the two NPU boards is equipped with a group of liquid leakage detection devices. Figure 3-10 shows the connections of the leakage detection cables. Table 3-9 describes the mapping between the cable ends.
No. |
Description |
Part No. |
---|---|---|
1 |
Cable from the left NPU board (J1031) to the leakage detection board at the bottom left |
04080584-007 |
2 |
Liquid leakage detection cable from the water inlet pipe of the left NPU board to the liquid leakage detection board |
- |
3 |
Liquid leakage detection cable from the water outlet pipe of the left NPU board to the liquid leakage detection board |
- |
4 |
Cable from the right NPU board (J1031) to the leakage detection board on the right |
04080584-008 |
5 |
Liquid leakage detection cable from the water outlet pipe of the right NPU board to the liquid leakage detection board |
- |
6 |
Liquid leakage detection cable from the water inlet pipe of the right NPU board to the liquid leakage detection board |
- |