Drive Configuration
Drive Configuration
Table 2-7 Drive configuration
Configuration
Maximum Front Drives
Drive Management Mode
2 x 2.5" SATA + 3 x 2.5" NVMe drive configuration [1]
5
Slots 0 to 1 support only SATA drives.
Slots 7 to 9 support only NVMe drives.
Connected to a CPU using SATA
2 x 2.5" SAS/SATA + 3 x 2.5" NVMe drive configuration [2]
5
Slots 0 to 1 support only SAS and SATA drives.
Slots 7 to 9 support only NVMe drives.
1 x RAID controller card
3 x 2.5" SAS/SATA + 6 x 2.5" NVMe drive configuration [3]
8
Slots 0 to 1 support only SAS and SATA drives.
Slots 2 to 3 and slots 6 to 9 support only NVMe drives.
1 x RAID controller card
2 x 2.5" SATA + 6 x 2.5" NVMe drive configuration [4]
8
Slots 0 to 1 support only SATA drives.
Slots 2 to 3 and slots 6 to 9 support only NVMe drives.
Connected to a CPU using SATA
2 x 2.5" SATA + 8 x 2.5" SAS/SATA drive configuration [5]
10
Slots 0 to 1 support only SATA drives.
Slots 2 to 9 support only SAS and SATA drives.
Connected to a CPU using SATA
1 x RAID controller card
[1]: Slots 0 and 1 do not support drive fault indicators. Slots 2 to 6 are empty and do not support drives.
[2]: Slots 2 to 6 are empty and do not support drives.
[3]: Slots 2 to 3 and slots 6 to 9 support only x2 PCIe link width. Slots 4 and 5 are empty and do not support drives.
[4]: Slots 0 and 1 do not support drive fault indicators. Slots 2 to 3 and slots 6 to 9 support only x2 PCIe link width. Slots 4 and 5 are empty and do not support drives.
[5]: Slots 0 and 1 do not support drive fault indicators.