Securing a Unit
- Determine the installation position on the ground based on the hole dimensions, and move the unit to the installation position using a pallet truck.Figure 4-12 Hole dimensions on the floor (unit: mm)
If you need to secure the unit to a base, see Base Dimensions. Secure it to the base using four M12x45 bolt assemblies and install anchor baffle plates.
- Secure the unit.
- Secure the unit to the ground or base using four M12 bolts.
- Secure the anchor baffle plate to the fan side using eight M5x10 tapping screws.
- If the air duct is not connected, seal the fan side.
- Obtain the anchor baffle plates according to the packing list.
Figure 4-13 Securing the unit to the floorFigure 4-14 Securing the unit to a baseAfter the unit is secured, seal the base on the fan side.