Figure 2-3 shows the indicators and buttons on the front panel of a server.
Figure 2-3 Indicators and buttons on the front panel![]()
1
|
UID button/indicator
|
2
|
Health indicator
|
3
|
Power button/indicator
|
4
|
Fault diagnostic LED
|
5
|
Drive Fault Indicator (Yellow Indicator)
|
6
|
Drive Activity Indicator (Green Indicator)
|
7
|
Fan module indicator
|
-
|
-
|
Table 2-2 Indicators and buttons on the front panelSilkscreen
|
Indicator/Button
|
State Description
|
![]()
|
Fault diagnostic LED
|
- ---: The server is operating normally.
- Error code: A server component is faulty.
For details about error code, see Atlas 800 AI Training Server iBMC (V3.01.00.00 or Later) Alarm Handling (Model 9010).
|
![]()
|
Power button/indicator
|
Power indicator
- Steady yellow: The server is in the standby state.
- Steady green: The server is properly powered on.
- Blinking yellow: The iBMC is starting.
- Off: The server is not connected to a power source.
Power button
- When the server is powered on, you can press this button to shut down the OS.
- When the server is powered on, you can hold down this button for 6 seconds to force the server to power off.
- When the server is in the standby state, you can press this button to start the server.
|
![]()
|
UID button/indicator
|
The UID button/indicator helps identify and locate a device.
UID indicator:
- Off: The device is not being located.
- Blinking blue (blinking 255 seconds): The device has been located and is differentiated from other devices that have also been located.
- Steady blue: The device is being located.
UID button:
- You can turn on, turn off, or blink the UID indicator by pressing the UID button on the panel or by using the iBMC CLI or WebUI.
- You can press this button to turn on or off the UID indicator.
- You can press and hold down this button for about 5 seconds to reset the iBMC.
|
![]()
|
Health indicator
|
- Steady green: The server is operating properly.
- Blinking red at 1 Hz: A major alarm has been generated on the server.
- Blinking red at 5 Hz: A critical alarm has been generated on the server.
|
![]()
|
Fan module indicator
|
- Off: The fan module is not powered on.
- Steady green: The fan modules are operating properly.
- Blinking red: An alarm is generated for a fan module.
|