Testing the Fan Module Redundancy
Testing the Fan Module Redundancy
Case No.
4.3.2
Objective
To check whether fan modules on the server work in redundancy mode.
Test Networking
See the test networking diagram.
Prerequisites
The server is properly powered on.
A Linux OS has been installed on the server.
Procedure
Access the OS after the server is powered on.
Log in to the iBMC WebUI, and query the current fan speed.
Remove a fan module of the server randomly and check whether the OS can be accessed.
Log in to the iBMC WebUI, and query the current fan speed.
Expected Result
After a fan module is removed, the OS is operating properly, and the speed of other fans increases for ensuring system heat dissipation.