Mounting PDUs in the Left and Right Racks
Background
- If a 65-inch Samsung display is used, five 1-outlet PDUs need to be installed on the racks.
- If a 70-inch SHARP display is used, one 1-outlet PDU needs to be installed in the left and right racks, respectively.
They are installed in the same way. The following procedure uses one of them as an example.
Procedure
- Orient the 1-outlet PDU ports upward and place the PDU on the right of the audio power amplifier in the right rack, as shown in Figure 6-27.
- Tighten one M6 x 16 hex socket screw at each end, as shown in Figure 6-27.
- Install the other 1-port PDUs in the same way.
- (For the TP3206-70 G2 and TP3218-70 G2) Install one 1-outlet PDU on the left of the audio power amplifier in the left rack.
- (For the TP3206-65 G2 and TP3218-65 G2) Install the other four 1-outlet PDUs, as shown in Figure 6-28.