When the system type is FusionModule500/800, perform the following steps to configure it.
Context
- The initial startup password authentication is required only during initial power-on commissioning. If the authentication has been performed successfully, no authentication is required afterward.
- The startup password needs to be authenticated when you restore the default settings on the WebUI or by pressing keys.
- If the startup password authentication is not complete, the ECC800-Pro WebUI and app cannot be used for commissioning.
- When the system type is changed to FusionModule500/800, the startup password needs to be authenticated again.
Procedure
- Authenticate the startup password on the WebUI.
- Log in to the ECC800-Pro WebUI as an administrator.
- Record the values of Barcode and Verify Code in the displayed Startup Password dialog box.
- Within 24 hours, inform Huawei technical support of Barcode and Verify Code to obtain the password. After obtaining the password, enter the password in the Password text box and click Submit to complete the authentication of the startup password.
The verification code is valid for 24 hours by default. After the validity period expires, the verification code is automatically updated. You can also click to update the verification code.
- Choose and set System type to FusionModule500/800.
- Use the Service Expert app to authenticate the startup password.
- Download and install the Service Expert app from Huawei AppGallery.
Before the installation, ensure that the PAD has connected to the Internet and the network is running properly.
- Hold down the SW button on the ECC800-Pro for less than 3s to enable the WiFi function.
- The initial password is Changeme after the WiFi function is enabled. The password is valid only after you hold down the button for the first time to enable the WiFi function. If you enable the WiFi function on the WebUI, there is no preset password.
- After WiFi is enabled by pressing the button, the PAD prompts the customer to change the default password when logging in to the app.
- After you disable the WiFi hotspot function on the WebUI and press the button again, the WiFi function is still enabled. In this case, the WiFi password is the one you changed last time.
- The WiFi function is disabled by default. If you need to enable the WiFi function, change the WiFi password to ensure connection security.
- A password that has been used for a long time is more likely to be stolen or cracked. The risk increases along with the time of use. Change the WiFi password periodically (recommended: once half a year).
- Use the Service Expert app to authenticate the startup password.
- Open the PAD app, and log in to the FusionModule500 device login page using the administrator account.
Ensure that the IP address is 192.168.245.10, the default administrator name is admin, and the default password is Changeme.
- If the message displayed on the page is changed from "Initial startup password authentication" to "Activated", the startup password authentication is complete.
- After the first login, change the password in time to ensure system access security.
- A password that has been used for a long time is more likely to be stolen or cracked. The risk increases along with the time of use. Change the password once every three months.
- It is recommended that you use different user names to log in to both the ECC800-Pro WebUI and app at the same time. If you use the same user name to log in to the WebUI and app at the same time, either of them will be forcibly logged out.
- The iDCService app supports only the Android system.
- The iDCService app is available only in Chinese.