Configuring Event Notification
You can set alarm notification by email or SMS as required. Information about a maximum of 20 users who will receive alarm notification can be displayed.
Prerequisites
To implement alarm notification by SMS, the following conditions must be met:
- The ECC800-Pro is configured with a 4G module and supports standard SIM card access.
- The ECC800-Pro is connected to a network with an email server through a WAN port. Both the Internet and local area network (LAN) are supported.
To use the WeChat notification function, connect the ECC800-Pro to the EDCM system. For details, see the user guide of the EDCM system.
Procedure
- Choose .
- Set related outbox parameters.
If Test email sending failed is displayed, check whether the receiver's email server requires CA certificate verification. If it is required, download the CA certificate from the receiver's email website and upload it in the Mailbox Certificate area.
Figure 5-11 Email setting pageThe following email addresses are for reference only (the actual parameters apply) and are used only for configuring the email function.
Table 5-15 Main parameters on the outbox configuration pageEmail Type
Email Server Domain Name
Mailbox Server IP Address
Encryption Mode and SMTP port
Remarks
Sina Mail
smtp.sina.com
How to obtain:
- Click Start on the PC, enter cmd in Running area, and press Enter to access the administrator page.
- Enter ping email server domain name at the position of the blinking cursor and press Enter to obtain email server IP addresses.
Non-encryption: 25
- The email server must comply with the standard SMTP protocol to ensure that the email sending and receiving functions are normal.
- Enter the email client authorization password at Password for 163 Mail, 126 Mail, and QQ Mail.
- If the email type is not in the list, set parameters by referring to the help information of the email type.
163 Mail
smtp.163.com
Non-encryption: 25; SSL encryption: 465
126 Mail
smtp.126.com
Non-encryption: 25; SSL encryption: 465
QQ Mail
smtp.QQ.com
SSL encryption: 465
Sohu Mail
smtp.sohu.com
Non-encryption: 25
139 Mail
smtp.139.com
Non-encryption: 25
Hotmail
smtp-mail.outlook.com
TLS encryption: 587
189 Mail
smtp.189.com
Non-encryption: 25
- Add an email address to receive emails.
The email address is used only for configuring the email function and is not used for other purposes. The address is encrypted during transmission in the ECC800-Pro to ensure that the personal data of users is fully protected.
Figure 5-12 Adding an email address to receive emailsClick Test to check whether the added mailbox is available. If it is available, Successfully to send the test email. is displayed. If it is unavailable, Failed to send the test email. is displayed. Check whether the receiver's mailbox parameters for receiving emails are correctly set.
- Add a mobile number to receive event notifications.
The mobile phone number is used only for configuring the SMS function and is not used for other purposes. The phone number is encrypted during transmission in the ECC800-Pro to ensure that the personal data of users is fully protected.
Figure 5-13 Adding a mobile numberClick Test to check whether the added mobile phone number is available. If it is available, Successfully to send the test short message. is displayed. If it is unavailable, Failed to send the test short message. is displayed. Check whether the mobile phone number is correctly set.
- Set the alarm notification delay parameter and the new alarm notification parameter.Figure 5-14 Setting the alarm notification parametersFigure 5-15 Adding alarm notification
Mailbox Address in Alarm Notification can be selected after it is added in Mailbox Settings. Mobile Phone Number can be selected after it is added in SMS Settings.
- Click Confirm to access the re-authentication page. Enter Login password and click Submit.
Follow-up Procedure
To modify or delete the email parameter settings, click Modify or Delete.
If the email address fails to be set, rectify the fault based on the handling suggestions of the error codes listed in the following table. If an error code is not listed in the following table, provide the ECC run log and contact Huawei technical support.
Type |
Error Code |
Suggestion |
---|---|---|
Failed to resolve the domain name. |
2 |
|
3 |
|
|
5 |
Check whether the IP address corresponding to the domain name of the email server is configured. |
|
11 |
|
|
Failed to connect to the email server. |
22 |
|
100 |
Check whether the local network cable is properly connected and whether the network adapter is activated. Ensure that the local network connection is normal. |
|
101 |
Check the firewall and router configurations between the ECC and the email server to ensure that the ECC communicates with the email server properly. |
|
110 |
|
|
111 |
Check whether the email server is running properly and whether the service port is started properly. |
|
112 |
Check whether the email server is running properly. |
|
113 |
Check the firewall and router configurations between the ECC and the email server to ensure that the ECC communicates with the email server properly. |
|
Failed to establish a secure connection. |
1 |
|
Failed to send the test email. |
504 |
Check whether the outbox address matches the user name for logging in to the email server. |
535 |
|
|
553 |
Check whether the outbox address matches the user name for logging in to the email server. |
|
530 |
On the outbox configuration page, set Encryption mode to SSL. |
|
554 |
|
|
550 |
|
|
421 |
Reduce the email sending speed or contact the third-party email server personnel to increase the email server configuration limit. |
|
450 |
Contact the personnel of the third-party mail server to add the sender address to the whitelist and do not limit the sending rate. |
|
451 |
Provide ECC run logs and contact the service center to reduce the email sending frequency. |
|
534 |
Log in to the sender's mailbox client and enable the access to the insecure applications. |