Installing a CE6865 Switch
Procedure
- Determine the position of the switch in the cabinet.Figure 8-51 Switch positions
- Install a switch.
- Two persons are required to install the device. One faces the front view of the cabinet, and the other faces the rear view of the cabinet.
- To prevent device damage or personal injury, hold the bottom of the device with both hands when installing it.
- When installing a CE6865 switch, align it with the rear panel of a compute node.
- Remove the ground screw from the ground point of the switch, as shown in Figure 8-52.
- Install mounting ears. Tighten the 12 countersunk screws on the left and right mounting ears on both sides of the switch, as shown in Figure 8-53.
- Push the switch into the cabinet horizontally from the front of the cabinet. See (1) in Figure 8-54.
- Tighten the screws to secure the left and right mounting ears to the front mounting bars of the cabinet. See (2) in Figure 8-54.
- (Optional) Tighten the screws that secure the scabbards and the left and right mounting ears. See Figure 8-55.
- Use a Phillips screwdriver to tighten the ground screws from the switch, as shown in Figure 8-56.
- Connect cables to the switch. For details, see Cable Connection.
- Check indicator status.
For details, see the user guides of CloudEngine 6800 Series Data Center Switches.