Q: What is the difference in LDP neighbor setup of NE80/NE40 between V3.1 and V3.3? 

Alarm Information

Null

Handling Process

A: For NE80/40 at VRP3.1, two equipment could set up multiple LDP neighbors through direct-connected interfaces. For the consideration of interconnection with equipment from C company, VRP3.3 is changed to that only one LDP neighbor could set up between two devices, through loopback interface address by default. If two neighbors are set, one is valid, and the other will be denied. 