Support of SSM and SSM2 in Metro 1000

Publication Date:  2012-07-24 Views:  148 Downloads:  0

Issue Description

Which hardware and software versions of Metro 1000 equipment support SSM and SSM2 protocol?

Alarm Information

Customer works with Huawei already 3 years and has a large network. This network contains many Metro 1000 sites. Now customer wants to run SSM (or in some parts SSM2) protocol on a network. Planning department of customer requests information about  which hardware and software versions of Metro 1000 supports SSM and/or SSM2 protocols.

Handling Process

All 1000 popular version can support Extended SSM, so 
here we only discuss what can support Standard SSM:
42SCB can not support Standard SSM.
43SCB 4.2.6.40 and above version can support Standard SSM, and the STG
BIOS must be 130; 4.2.6.41P02 and STG BIOS 130 is recommended.

Root Cause

Function and feature

Suggestions

 none.

END