No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ-Whether the SBC23000 support the Signaling and Media separate Map

Publication Date:  2012-08-09 Views:  157 Downloads:  0

Issue Description

Q: Whether the SBC23000 support the Signaling and Media separate Map ?

Alarm Information

Null

Handling Process

A: The SBC2300 support the Signaling and Media separate Map, you can use different physical ports and IP addresses to represent the signaling and bearer. 
For example:
 sbc signal-addrmap clientaddr 203.126.203.3 serveraddr 192.168.1.8  softxaddr 192.168.1.10
#
sbc media-addrmap clientaddr 203.126.203.3 serveraddr 192.168.3.8 weight 50

Root Cause

Null

Suggestions

 
None