FAQ-Points for Attention in Link Binding of NE40 E1&CE1

Publication Date:  2012-07-27  |   Views:  150  |   Downloads:  0  |   Author:  Xu Peigao  |   Document ID:  EKB0000173585

Contents

Issue Description

Q: What should be noted in the link binding of NE40 E1/CE1? 
      

Alarm Information

Null
      

Handling Process

A: NE40/80 support MP through hardware; namely, the functions are realized by interface board. At present, only cpos, 8CE1 and 8CT1 support MP.
8CE1 and 8CT1 support it through DSP; the hardware of 8E1 has no DSP, so it does not support MP.
Additionally, NE40/80 do not have virtual template, so they cannot realize binding through virtual-template.
Therefore, the binding of 2M link of NE40/80 can only be realized through MP-GROUP, and only 8CE1 and 8CT1 interface board can realize binding. 
      

Root Cause

Null

Suggestions