No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

For Two FEs under NE40 Eth-trunk One-way is Reachable because of 2500 + Transmission Problem

Publication Date:  2012-07-27 Views:  90 Downloads:  0

Issue Description

Topology: NE40----2500 + transmission----2500 + transmission ----NE40
Two FEs of NE40 act as eth-trunk and one-way is reachable.
      

Alarm Information

Null

Handling Process

1. NE40 configuration is not problematic.
2. 2500 + does not support eth-trunk binding. After NE40 FE binds, it has only one MAC address. 2500 + can only recognize one of bound FE port. 2500 + does not support binding and one-way is reachable. NE40 cancels trunk  binding.
      

Root Cause

1. Two FEs of NE40 act as eth-trunk . Cable or configuration is problematic.
2. The transmission is problematic.
      

Suggestions

Null
      

END