HP-TIM, HP-LOM and HP-UNEQ alarms on line boards

Publication Date:  2019-07-04 Views:  282 Downloads:  0

Issue Description

After cutover (integration one OSN 2500 to existing network) HP-TIM, HP-LOM and HP-UNEQ alarms appeared on line boards on Metro 1000.
szhw>
:alm-get-curdata:0,0
@@@@@@@@@@@@@@@@@ Message from 0xx @@@@@@@@@@@@@@@@@@
                                                                                                              
                                                  ALM SUMMARY                                                 
  NUM         BID   EID         SEVE        STATE       START-TIME           END-TIME             PARAS       
  14502       11    HPTIM       minor       start       2006-9-15 0:55:32    None                 0x01ffff01  
  14503       11    HPTIM       minor       start       2006-9-15 0:55:32    None                 0x02ffff01  
  14504       11    HPTIM       minor       start       2006-9-15 0:55:32    None                 0x03ffff01  
  14505       11    HPTIM       minor       start       2006-9-15 0:55:32    None                 0x04ffff01  
  14507       11    HPLOM       major       start       2006-9-15 0:58:39    None                 0x03ffff01  
  14508       11    HPLOM       major       start       2006-9-15 0:58:39    None                 0x04ffff01  
  14510       11    HPUNEQ      minor       start       2006-9-15 0:58:43    None                 0x03ffff01  
  14511       11    HPUNEQ      minor       start       2006-9-15 0:58:43    None                 0x04ffff01  
  Total records :8  

Alarm Information

HP-TIM, HP-LOM, HP-UNEQ.

Handling Process

1. Configured at least one VC-12 path in each VC-4 (1,2,3 and 4) and HP-LOM and HP-UNEQ alarms disappeared.
2. After configuration at least one VC-12 path in each VC-4 we could manage content of J1 byte. Set it as usual as "HuaWei SBS " and HPTIM alarms dissappeared.

Root Cause

1. After alarms analizing it turned out that HP-LOM and HP-UNEQ alarms are reported on tnat VC-4 which are not loaded with traffic. 
2. Also when VC-4 is unloaded you cannot configure J1 byte to exclude HP-TIM.

Suggestions

If HP-TIM, HP-LOM and HP-UNEQ alarms are reported on line boards: 
1) configure at least one VC-12 channel in each VC-4.
2) configure J1 byte as "HuaWei SBS     " on each station.

END