E1 Connection Fails because Frame Format of AR2831 and C72XX is Inconsistent

Publication Date:  2012-07-27  |   Views:  50  |   Downloads:  0  |   Author:  Liu Zhengui  |   Document ID:  EKB0000255570

Contents

Issue Description

1. AR2831 uses (E1) S 1/0 to connect with CPOS of C72XX (CPOS converses as E1 and the intermediate transmission can be regarded as transparent and both interfaces cannot be up.
2. Remote loop 2831, AR2831 Serial1/0 current state: UP; remote loop 72XX, C7206 (CPOS) Serial2/0.1/1/4/3:0 is up; Unlock the loop and physical layers of both sides are down.

Alarm Information

On AR2831:
interface Serial1/0
 link-protocol ppp
 fe1 timeslot-list 1-31
 ip address 10.247.82.70 255.255.255.252
Serial1/0 current state :DOWN   
Line protocol current state :DOWN
Description : Serial1/0 Interface 
physical layer is E1-F, baudrate is 1984000 bps
 fe1 timeslot-list 1-31
The Maximum Transmit Unit is 1500, Hold timer is 10(sec) 
Internet Address is 10.247.82.70/30 
Link layer protocol is PPP 
LCP initial
On C72XX:
interface Serial2/0.1/1/4/3:0
 ip address 10.247.82.69 255.255.255.252
 encapsulation ppp
R1-C-MM(config)# sh  Serial2/0.1/1/4/3:0
Serial2/0.1/1/4/3:0 is down, line protocol is down 
  Hardware is Multichannel E1
  Description: MAOMING TO xinyi_chengdong
  Internet address is 10.247.82.69/30
  MTU 1500 bytes, BW 1984 Kbit, DLY 20000 usec,
     reliability 253/255, txload 1/255, rxload 1/255
  Encapsulation PPP, LCP REQsent, crc 16, Data non-inverted
  Keepalive set (10 sec)

Handling Process

Check physical layer of C72XX and it is found that their frame format is CRC4. The default format of the interface is no-crc4 and change it as crc4. The problem is solved. The command is fe1 frame-format { crc4 | no-crc4 }.

Root Cause

1. Both sides do not configure the clock.
2. The cable coding is inconsistent.
3. Frame format is inconsistent.

Suggestions

Null