FAQ-Can CON of MPU on NE80E Access the Terminal and Make Related Operation

Publication Date:  2012-07-27  |   Views:  140  |   Downloads:  0  |   Author:  Miao Guangya  |   Document ID:  EKB0000255623

Contents

Issue Description

Q:
Can con of MPU on NE80E access the terminal and make related operation?
        
 

Alarm Information

Null

Handling Process

A:
NE80E defaults that there is no output when Con of slave MPU accesses the terminal. There is no operation on the terminal. HOwever, login on the system and change default setting with the following command:
[Quidway-hidecmd]slave  command-line  accessible
And then the terminal accesses Con of slave MPU on NE80E and the command can be executed.
NE40E and NE5000E are similar to NE80E.

Root Cause

Null

Suggestions

It is suggested that the operation of configuration should be operated on master MPU.