FAQ-How to Remotely Check BOM of NE80

Publication Date:  2012-07-27  |   Views:  171  |   Downloads:  0  |   Author:  Gu Chunyang  |   Document ID:  EKB0000270012

Contents

Issue Description

Q:
How to remotely check BOM of NE80?

Alarm Information

Null

Handling Process

A:
1. Under diagnosis mode, use the following command to collect board information:
[HACZ-YFJ-R-NE80-01-diag]boardinfo read 1 board_1.txt
 Start to Read 01 board information
 Read information from 1 board success
2. Use more command:
<HACZ-YFJ-R-NE80-01>more board_1.txt
/$[ArchivesInfo Version]
/$ArchivesInfoVersion=2.0
/$[Log]
/$Log1=16286,030366230,2006-05-12
[Board Properties]
BoardType=CR01LPUE0
BarCode=0366231065000094
/$Item=03036623
/cDescription=line processing unit
/eDescription=Line Processing Unit Enhanced
/$PCBVersion=A
Manufactured=2006-05-12
ManufactureCode=1
/$CLEICode=
/$[Daughter Board Properties]
/$Daughter_BoardNum=0
/$[Software]
/$SoftwareNum=2
/$[Software_1]
/$ChipPosition=U38;
/$SoftwareName=software-CR01LPUB0-CR0LPUB01-BOOTROM(0-512K)
/$Item=05023706
/$Version=128
/$[Software_2]
/$ChipPosition=U21;
/$SoftwareName=software-CR01LPUB0-CR0LPUB03-EPLD
/$Item=05023708
/$Version=300
<HACZ-YFJ-R-NE80-01>
BarCode=0366231065000094,  the first 6 numbers of BarCode plus 03 is BOM. E.g. BOM is (03) 036623, the last bits represent manufacture name and serial.

Root Cause

Null

Suggestions

Null