Issue Description
Two V5 interfaces are created on one UA5000 with two LEs connected to one UA5000 on each V5 interface . EWSD is connected with V5 id = 0 and OCB is connected with V5 id = 2 .
Alarm Information
After setting the system parameters 1=7(CLIP only with EWSD ) and system parameter 1=5(clip is only with OCB)
clip is only with EWSD but not with OCB i.e single time only with one switch with the same UA5000
Handling Process
Mean:
System Parameter
name index: 1 Parameter value: 5
Mean: Overseas version flag, 0:China, 1:HongKong, 2:Brazil, 3:Egypt,
4:Singapore, 5:Thailand, 6:France, 7:Vietnam, 8:Bahrein
overseas parameter
Parameter name index: 49 Parameter value: 65534
Mean: Reserved parameter
AT OCB Switch end:
VERS=10(compatibale with Huawei DLC)
Root Cause
Following parameters need to be set in order to get normal CLIP with the EWSD and OCB exchange simaltaneously.
System parameter 1=7
overseas parameter 49 =65534
PVU Card version=PVUV100R011B02D055SP03
AT OCB Switch end:
VERS=10(Needs to verify from customer)
After setting these parameters we get CLIP on same UA5000 from both LE's(EWSD and OCB)
Suggestions
Set the above parameters at both ends LEs and UA5000 when u need to connect one UA5000 to two LE's ie OCB and ESWD.