The unused space in the VPR configuration table haven't been initialed that caused save-operation overrun 7 minutes

Publication Date:  2012-07-25  |   Views:  181  |   Downloads:  0  |   Author:  88583Eduardo Rodriguez  |   Document ID:  EKB0000346874

Contents

Issue Description

 Control Board - SCUA Version:MA5600V800R003C02B108SP001.
MA5600T MSAN maincontroller-board, SCUA, saved software process of database overrun 7 minutes.

Alarm Information

Null

Handling Process

We have followed these steps on maincontroller board: 
1.save configuration
2.active configuration (need to reboot system)
3.save configuration once more after system rebooted to check the problem is solved.

Root Cause

This problem was generated by the unused space in the VPR configuration table of maincontroller board's database. It hadn’t been initialed, which will induce system have to read some random value and spend a long time during compression-phase.

Suggestions

Null