Issue Description

OSN6800V1R3C02B01e, when we want to create GE end to end service after och level trail created, it promote wrong. There is no service trail for creating GE end to end.We couldn't create the GE trail.

Alarm Information

NO.

Handling Process

When we want to create GE end to end service, we should do the trail search before the och level trails were created.

Root Cause

We need OTU5G trails before creating GE end to end trails. The OTU5G trails can be searched after the och level trails were created.

Suggestions