No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

When a TBE Board Is Configured Only with a Unidirectional Cross-Connection, the Unidirectional Service Is Not Available. When the TBE Board Is Configured with Bidirectional Cross-Connections, the Bidirectional Service Is Normal; When a Unidirectional Cross-Connection Is Deleted, However, the Service

Publication Date:  2012-07-25 Views:  116 Downloads:  0

Issue Description

When a TBE board is configured only with a unidirectional cross-connection, the unidirectional service is not available. When the TBE board is configured with bidirectional cross-connections, the bidirectional service is normal; When a unidirectional cross-connection is deleted, however, the service becomes unavailable. 

Alarm Information

Null  

Handling Process

Configure the TBE board with bidirectional cross-connections. 

Root Cause

When a TBE board is configured with a unidirectional cross-connection, the PHY chip at the receive end becomes linkdown and cannot extract clock signals from the received data. The PHY chip needs to use the clock signal extracted from the received data when sending data. As a result, the PHY chip fails to send data and the unidirectional service is unavailable. 

Suggestions

Null 

END