Extended ECC modification problem

Publication Date:  2012-07-25 Views:  130 Downloads:  0

Issue Description

When we change mode of Extended ECC from specified to Auto mode the error message appeared (the extended ECC mode conflicted, error code 39122)

Alarm Information

Null

Handling Process

To over come this problem we must clear server and client first then change mode of Extended ECC from specified to Auto mode 

Root Cause

This problem appeared because when the Extended ECC mode was specified we already assigned port number to server and IP address and Port number to Client so we can't change the mode of Extended ECC from specified to Auto mode  

Suggestions

This issue not only appeared with OSN 3500 but also all NG SDH

END