No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ-OSN1500 AUX board Power_abnormal alarm parameter description

Publication Date:  2012-07-25 Views:  104 Downloads:  0

Issue Description

Q, OSN1500 AUX board Power_abnormal alarm parameter description

Alarm Information

Null

Handling Process

A, para0 fixed value 0x01; para1 fixed value 0x00; para2 fixed value 0x01; para3(transform into binary,bit=1 is available): bit0 // pick the board 1.5 V voltage value abnormal bit1 // pick the board 1.8V voltage value abnormal bit2 // pick the board voltage module 3.3 V voltage stage abnormal; bit3 // pick the board backup voltage module 3.3 V voltage stage abnormal

Root Cause

Null

Suggestions

recently, every version of OSN1500 equipment AUX board Power_abnormal alarm parameter definitions are all the same.

END