Huawei S3100 disk array unable to format successful

Publication Date:  2012-07-25  |   Views:  215  |   Downloads:  0  |   Author:  AUTHOR  |   Document ID:  EKB0000395837

Contents

Issue Description

The Huawei S3100 disk array is connected to Sun Server using fiber optic and connected to switch using ethernet cable. After configuring IP address, we initialize the disks of the disk array. After selecting the disk that needs to be formatted, it prompt out error message. Thus, we unable to format the selected hard disk.

Alarm Information

root@N2000Server # format
Searching for disks...done
c1t5d0: configured with capacity of 199.99GB
c1t5d1: configured with capacity of 199.99GB
AVAILABLE DISK SELECTIONS:
       0. c0t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /pci@0,600000/pci@0/pci@8/pci@0/scsi@1/sd@0,0
       1. c0t1d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /pci@0,600000/pci@0/pci@8/pci@0/scsi@1/sd@1,0
       2. c1t5d0 <ENGENIO-INF-01-00-0619 cyl 51198 alt 2 hd 128 sec 64>
          /pci@2,600000/SUNW,qlc@0/fp@0,0/ssd@w200500a0b850477b,0
       3. c1t5d1 <ENGENIO-INF-01-00-0619 cyl 51198 alt 2 hd 128 sec 64>
          /pci@2,600000/SUNW,qlc@0/fp@0,0/ssd@w200500a0b850477b,1
       4. c2t1d0 <ENGENIO-INF-01-00-0619 cyl 51198 alt 2 hd 128 sec 64>
          /pci@3,700000/SUNW,qlc@0/fp@0,0/ssd@w200400a0b850477b,0
       5. c2t1d1 <ENGENIO-INF-01-00-0619 cyl 51198 alt 2 hd 128 sec 64>
          /pci@3,700000/SUNW,qlc@0/fp@0,0/ssd@w200400a0b850477b,1
Specify disk (enter its number): 3
selecting c1t5d1
[disk unformatted]
Disk not labeled.  Label it now? y
Warning: error writing VTOC.
Illegal request during read
ASC: 0x94   ASCQ: 0x1
Warning: error reading backup label.
Illegal request during read
ASC: 0x94   ASCQ: 0x1
Warning: error reading backup label.
Illegal request during read
ASC: 0x94   ASCQ: 0x1
Warning: error reading backup label.
Illegal request during read
ASC: 0x94   ASCQ: 0x1
Warning: error reading backup label.
Illegal request during read
ASC: 0x94   ASCQ: 0x1
Warning: error reading backup label.
Warning: no backup labels
Write label failed

Handling Process

After Solaris 10 is installed, the MPxIO is loaded. To enable the MPxIO, do as follows:
Step 1 In Solaris, open the /kernel/drv directory. Then run the following command:
#vi fp.conf
Step 2 After opening the configuration file, modify mpxio-disable = yes as mpxio-disable = no.
Save the settings and exit.
Step 3 Run the following command:
#reboot -- -r
After Solaris is restarted, the MPXIO is enabled.

Root Cause

The MPXIO haven't enabled, thus we using failover network which each disk has two paths. For example, c1t5d0 and c2t1d0 is the same disk on S3100. We need to enable MPXIO to make two paths as one.

Suggestions

Remember to restart the server in order to enable the MPXIO enable successfully.