FAQ-Metro 1000 power on with -48V and -60V

Publication Date:  2012-07-25 Views:  111 Downloads:  0

Issue Description

Optix155/622H has been working with -48 V power supply.
Customer removed the equipment to other site, where the power supply system only support - 60 V. How to power the Metro1000 from -60 V

Alarm Information

Null

Handling Process

Just switch off the equipment, pull out -48V connector, insert -68V connector and power on the equipment.

Root Cause

Power supply board in Metro 1000 is SS42POIA. According to Hardware discription Power supply  Accesses has  two �48 V/�60 V option, but on there board there is only -48 V label. 
Customer is worring about any additional action to do to supply with -60 V

Suggestions

It is better to indicate both -48V/-60V variants on the Power supply board.