FAQ how solve problems about missing port name info in SHDSL board

Publication Date:  2012-07-25  |   Views:  146  |   Downloads:  0  |   Author:  Sergio Augusto Sosa  |   Document ID:  EKB0000438426

Contents

Issue Description

When do you check in the N2000 BMS V200R011C02B026  some boards SHDSL for MA5300 and MA5600 the column with port name is empty, that mean that the info about frame/slot/port is in blank.

Alarm Information

N/A only in the GUI not info appear about port name for some SHDSL boards.

Handling Process

first check if the table exist in the database, for that you need to execute the next commands
1>use BMSDB
2>go
1>sp_help 
2>go
then export the tables to check if the are some missing info.
to export you need to execute
bcp BMSDB..ma5600v3_shdl_PortTab out BMSDB..ma5600v3_shdl_PortTab.txt -Usa -Ppassword -SN2000DBServer -c
bcp BMSDB..ma5300_shdl_PortTab out BMSDB..ma5300_shdl_PortTab.txt -Usa -Ppassword -SN2000DBServer -c
and after check the export file and detect that is missing info you need to execute the next script for create the info again in the table.
this for MA5300
update BMSDB..ma5300_shdl_PortTab set PortName = Obj.Name
from BMSDB..bms_gdm_ObjectTab as Obj, MSDB..ma5300_shdl_PortTab as sdl
where Obj.ID0 = sdl.DevID
and Obj.ID1 = sdl.Frame
and Obj.ID2 = sdl.Slot 
and Obj.ID4 = sdl.Port
and this for MA5600
update BMSDB..ma5600v3_shdl_PortTab set PortName = Obj.Name
from BMSDB..bms_gdm_ObjectTab as Obj, BMSDB..ma5600v3_shdl_PortTab as sdl
where Obj.ID0 = sdl.DevID
and Obj.ID1 = sdl.Frame
and Obj.ID2 = sdl.Slot 
and Obj.ID4 = sdl.Port

Root Cause

that is because the info in the table ma5600v3_shdl_PortTab and ma5300_shdl_PortTab is empty for some DSLAM.

Suggestions

after execute the script can pass about 10 minutes all depends of the quantity of Devices.
is better if you can restart the database after execute the script but is not mandatory.