MOD_TYPE_MISMATCH alarm on Card N2EGT2

Publication Date:  2012-07-25 Views:  135 Downloads:  0

Issue Description

When N2EGT2 card is used with electrical ethernet SFP, there is an alarm on NE called MOD_TYPE_MISMATCH but traffic is up.

Alarm Information

MOD_TYPE_MISMATCH

Handling Process

Solution: set the port to electrical interface.
:cfg-replace-port:Bid,Pid,porttype,portlevel;
            Bid: 1~8,11~16(40G)/17(80G);
            Pid: 1~16
            porttype: sdh-opport, sdh-eport
            portlevel: sdh:stm-1, stm-4,stm-16,stm-64
            eth:ge
            SAMPLE:
           sdh:cfg-replace-port:1,1,sdh-opport,stm-4;
           eth:cfg-replace-port:1,1,sdh-eport,ge;

Root Cause

N2EGT2 default is optic interface board, so the port of N2EGT2 default is optic interface.  In this case, the port use Electrical SFP module, so it is report alarm of
 MOD_TYPE_MISMATCH.
Solution: set the port to electrical interface.
:cfg-replace-port:Bid,Pid,porttype,portlevel;
            Bid: 1~8,11~16(40G)/17(80G);
            Pid: 1~16
            porttype: sdh-opport, sdh-eport
            portlevel: sdh:stm-1, stm-4,stm-16,stm-64
                       eth:ge
            SAMPLE:
           sdh:cfg-replace-port:1,1,sdh-opport,stm-4;
           eth:cfg-replace-port:1,1,sdh-eport,ge;

Suggestions

None