No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade
Knowledge Base

FAQ-What Are the Formats for the Charging Pulse and Signal in the H248 Signaling Sent by Company A

Publication Date:  2012-07-25  |   Views:  227  |   Downloads:  0  |   Author:  Chang Yuan  |   Document ID:  EKB0000457949

Contents

Issue Description

Q:
What are the formats for the charging pulse and signal in the H248 signaling sent by company A?

Alarm Information

Null

Handling Process

A:
The softswitch of company A uses the SG packet of the MODIFY message to issue the charging pulse and times. The detailed format is as follows: Signals{amet/mpb{bpc=1}}
mpb:Metering Pulse Burst,This signal causes a burst of metering pulses to be applied to the termination. //Charging pulse
bpc:Burst Pulse Count,This parameter specifies the number of metering pulses to be applied as a burst on the line. The type, duration and pulse repetition interval for the metering pulses comprising the burst are provisioned in the MG.   //Charging pulse times. Integer type. Default value: 1.
      

Root Cause

Null

Suggestions

Null