FAQ-What Are the Precautions for Configuring RRPP on the S9300

Publication Date:  2012-07-27  |   Views:  120  |   Downloads:  0  |   Author:  b00122918  |   Document ID:  EKB0000487949

Contents

Issue Description

 What are the precautions for configuring RRPP on the S9300? 

Alarm Information

 Null 

Handling Process

 The precautions for configuring RRPP on the S9300 are as follows:
1. Limited by hardware specifications, RRPP can use a maximum of 96 and 144 ACL rules on 24-port and 48-port boards. You must allocate ACL rules properly on a network where multiple RRPP rings are used.
2. RRPP and MSTP cannot be used on the S9300 simultaneously; therefore, STP must be disabled on interfaces of RRPP rings.
3. The RRPP convergence speed is related to the number of domains and rings. A smaller number of domains and rings represents faster RRPP convergence. 
 

Root Cause

 Null 

Suggestions

 Null