Alarm REM_SF is reported by error because of some operation.

Publication Date:  2012-07-25 Views:  119 Downloads:  0

Issue Description

REM_SF alarm  is reported.
NE Software 5.51.05.26

Alarm Information

REM_SF alarm 

Handling Process

 It can be solved by switching the service.
Please switch the service from 10GE lan to STM64,then switch the service from STM64 to 10GE lan,then the Alarm REM_SF can be cleared.
The process don't cause the service.

Root Cause

The problem is caused by some operations.  
If you have the follow operations, REM_SF alarm can be reported by error.
1.delete the logical slot for 12TDX and then reset 12TDX by hardware.
2.add the logical slot and then reset 12TDX by sftware.
3.configure the service as 10GE lan

Suggestions

REM_SF alarm can be reported by error because of some operation.