FAQ-How to print the OMCI message on GPB board

Publication Date:  2012-07-25  |   Views:  386  |   Downloads:  0  |   Author:  huangyunxian  |   Document ID:  EKB0000516829

Contents

Issue Description

Q:
MA5600T V800R007+GPBC/GPBD board
Question: we often met the problem regarding ONTconfig failed, or the ONT feedback error when process the OMCI message. Usually R&D will request to print the OMCI message to investigate, How to print the OMCI message properly? here you can find the answer. Notice:There is a big amount of OMCI message between OLT and ONT, so we need select the specified ONT to print out them.


Alarm Information


Null


Handling Process

A:
MA5600T(config)#diagnose

MA5600T(diagnose)%%su

-----------input the su password here------

MA5600T(su)%%transparent on /

MA5600T(su)%%user

MA5600T(su)%%omci set debug_ont ----select the ONT

MA5600T(su)%%omci set printswitch exceptmsgtype 14 // filter the mib upload message. Input this command for "OMCI process failed" problem only, no need this command for the ONT config failed problem,

MA5600T(su)%%omci set printswitch on 1

Here reset ont or input the command that cause ont confiuration failed or omci process failed;

MA5600T(su)%%omci set printswitch off 1

MA5600T(su)%%transparent off


Root Cause


Null


Suggestions

Null