No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Due to the switch have been changed during upgrade, after upgrade to U2000 we can't use IP fix on device in TL1 command

Publication Date:  2012-07-25 Views:  108 Downloads:  0

Issue Description

Before upgrade to U2000, we can use IP Address to fix on device in TL1 command. such as DEV=10.10.10.1
But after we upgrade to U2000, when we input DEV=10.10.10.1 it will get error(The device does not exit)
      

Alarm Information

Null
      

Handling Process

To change this switch, we need do the operations as follows:
1 Execute the command in the database
update BMSDB..bms_cfg_tab set CfgValue='1' where strLocateName='AN.NBFRAME' and CfgName='DEVMEAN'
go
2 Reboot TL1NBiDm Process in the sysminitor 

Root Cause

In TL1 command usually we use DEV = Device Name fix on device, and we have a switch in the database to denote this item DEV is Device Name or Device IP address.   we can check this switch as follows:
Execute the command in the database as follows:
select CfgValue from BMSDB..bms_cfg_tab where strLocateName='AN.NBFRAME' and CfgName='DEVMEAN'
go
If the result is 0 then it denote that this item "DEV" is Device Name
If the result is 1 then it denote that this item "DEV" is Device IP Address
After we check this switch on current U2000, It is0, so we need change it to 1.  Then we can use IP address fix on device.
      

Suggestions

NULL

END