How to create service between IFE2(RTN V1) and IFU2 (RTN V3)

Publication Date:  2012-07-25  |   Views:  137  |   Downloads:  0  |   Author:  Edmond  |   Document ID:  EKB0000548895

Contents

Issue Description

Customer can not  configure radio link between ife2 (rtn v1) and ifu2 (rtn v3).
version:
microwave:
optix rtn900v1r3c00 and optix rtn900 v1r2c01&c02;
u2000: u2000-t v1r3c00spc101

Alarm Information

None

Handling Process

how to configure radio link based on this scenario:
on the ne which have ifu2 board:
1. the current e1 quantity is zero;
2. enable the "ieee-1588" timeslot in gui "if attributes" of ne explore.
then we can create the link between ife2 and ifu2.

Root Cause

according to the the interconnection rules between the air interfaces of the optix rtn900v1r3c00 and optix rtn900 v1r2c01&c02:
when working only in pure ethernet mode, the ifu2 board can be interconnected with the ife2 board through the air interface. when working in hybrid mode that transmits e1 and ethernet services, the ifu2 board cannot be interconnected with ife2 board through the air interface.

Suggestions

We must know clearly about the all application for the equipment aracteristic.