R_SLIP alarm due to board is moved

Publication Date:  2012-07-25 Views:  116 Downloads:  0

Issue Description

One day ,engineer report there is R_SLIP alarm rise in a 1600G .
Its version is v1r5

Alarm Information

R_SLIP

Handling Process

1.There is not other alarm
2.ST2 board was moved to other slot
3. Change the clock tracing to the new slot of st2 ,alarm disappear

Root Cause

The st2 board was moved to another slot but configuration of time trace is not changed .

Suggestions

There is still clock tracing configuration in 1600G .So ,its configuration should be checked when the R_slip and T_slip alarm rise .