Handling Process
Solution 1:
Log in to the blade server where the IP address of the BMC cannot be changed, and then execute the following command.
[root]# ipmitool mc reset cold
By doing this, the BMC can be restarted in the operating system, and the BMC network port is refreshed.
Solution 2:
Remove and insert the blade server where the IP address of the BMC cannot be changed to manually restart the BMC.
Root Cause
The baseboard management controller (BMC) of the E6000 cannot communicate with the management module (MM) through the network port. In this condition, the BMC needs to be restarted.