Publication Date: 2012-07-22 | Views: 840 | Downloads: 0 | Author: anliku | Document ID: EKB1000010804
Unable to deploy storage devices as they cannot be started properly.
...... Aug 25 09:29:24 Oceanspace kernel: [70703]1.Add vault disk(Slot id: 3, WWN: 200000188278cf68) ...... Aug 25 09:29:24 Oceanspace kernel: [70717]sda: Unit Not Ready, sense: Aug 25 09:29:24 Oceanspace kernel: [70717]Current : sense key Hardware Error Aug 25 09:29:24 Oceanspace kernel: [70717]Additional sense: Internal target failure Aug 25 09:29:24 Oceanspace kernel: [70732]sda : READ CAPACITY failed. Aug 25 09:29:24 Oceanspace kernel: [70744]Handle VaultDisk fail ......
By locating the Slot id that is closest to the strings Handle VaultDisk fail, the slot of the coffer disk that is in question can be identified. The coffer disk in slot 3 failed the capacity detection, as shown above.
...... Aug 25 09:29:24 Oceanspace kernel: [70766]Find no CtrlFrame Aug 25 09:29:25 Oceanspace kernel: [71745]There is not vault disk,now discard all event ......
Conclusion:
This fault can also be removed by upgrading the storage software to 1.03.01.108.T03 or later.