No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration for the Two-node cluster hot backup lost

Publication Date:  2012-09-13 Views:  416 Downloads:  0

Issue Description

Two USG5330 to do the Two-node cluster hot backup, when the electricity cut down and the equipments restart, one of the USG5330 loss a part of configuration, result in the different configuration of two USG5330, some operations can’t run normally.

Alarm Information

none

Handling Process

Import the configuration from the USG5330 which has the whole configuration to the USG5330 which loss the configuration by batch manually. 

Root Cause

The USG5330 which loss the configuration didn’t save the configuration before the cut down of electricity.

Suggestions


When we change the configuration at one USG5330, and synchronized at another USG5330, we should save the configuration at the second USG5330.

END