No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MCU cascading transmission linecables diameter is slender caused can not be cascaded

Publication Date:  2012-09-22 Views:  155 Downloads:  0

Issue Description

The two MCU cascade can not achieve interoperability

Alarm Information

None

Handling Process

After many experiments, replace the cascading transmission line with thicker cables, problem can be solved.

Root Cause

One of the MCU is far away from the transmission room while no relay equipment between then, transmission quality can not be guaranteed led to can not be cascaded Replaced with thicker wire diameter cable, problem can be solved.

Suggestions

None

END