No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Summarization of MCU’s E1 cascade in Hunan Railcom

Publication Date:  2012-09-26 Views:  301 Downloads:  0

Issue Description

Networking:
One MCU in Changsha Railcom with a set of platform software- VBILL, RMCC, GKM, GK, local manage platform;
One MCU in Huaihua Railcom without platform software has local manage platform

Alarm Information

MCUs in Changsha and Huaihua cascade, when there is only chairman in one conference, the main meeting place under Changsha MCU can’t watch meeting place in Huaihua freely; or Changsha MCU and Huaihua MCU both have a chairman in one conference- that is two chairmen in one conference.

Handling Process

Check the accessory.

Root Cause

The problem is related to cascade method. One is local manage platform cascade, one is RMCC cascade.

Suggestions

None

END