No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade
Knowledge Base

Precautions of operation network mcu press testing

Publication Date:  2019-07-24  |   Views:  132  |   Downloads:  0  |   Author:  SU1000864011  |   Document ID:  EKB1000016300

Contents

Issue Description

Operation network (main devices: GK/RMCC/Schedule/vBbil/8620MCU are in the same network segment) do press testing to MCU(IP). Use virtual terminal software OT of our company to test.
The frequent problems:
1. OT fails to register
2. Use method of OT
3. The mode of holding conference
4. Fail to hold a conference by Schedule Web, it says users data is damaged.

Alarm Information

none

Handling Process

1. The terminal of operation network is certificated by account and password which are provided by vBill. OT does not support password certification, so you must modify register mode on GK node to IP register or GK dynamic register, this test uses  node dynamic register mode, it need license support of GK. GK of main and backup need only one license, and only when the two GK service are stopped can you replace it. Then run OT and it can be registered.
2. Reference OT help, configure and run many parameter by batch processing .
3. GK uses dynamic register mode, there is no node information on rcmm. The only way to hold conference is Schedule Web to add OT node number.
4. GK uses dynamic register mode, there is no users information on vBill, so it cannot accounting by certification. Set AAARep=0 in RMCC.ini file. Delete certification accounting option in GK property of GKM.

Root Cause

none

Suggestions

 When doing press testing to MCU, consider roundly. According the fault, examine and solve the problems.